Performance Data Cooling

Performance Data Cooling

4YCY4030A1 AT 1000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

29.8

24.1

26.9

29.2

28.9

2.3

85

63

31.0

19.7

22.6

25.5

27.4

2.3

67

33.4

15.8

18.6

21.5

23.4

2.3

 

 

71

36.1

11.8

14.6

17.5

19.4

2.3

 

59

27.3

23.0

25.8

27.3

27.3

2.5

95

63

28.5

18.7

21.5

24.4

26.3

2.5

67

30.7

14.7

17.6

20.4

22.3

2.5

 

 

71

33.1

10.7

13.6

16.5

18.4

2.5

 

 

 

 

 

 

 

 

 

59

24.8

21.9

24.7

24.8

24.8

2.7

105

63

25.9

17.6

20.5

23.3

25.2

2.7

67

27.9

13.7

16.5

19.4

21.3

2.7

 

 

71

30.1

9.7

12.6

15.4

17.4

2.7

 

 

 

 

 

 

 

 

 

59

22.4

20.8

22.4

22.4

22.4

2.9

115

63

23.3

16.6

19.5

22.3

23.3

2.9

67

25.1

12.7

15.5

18.4

20.3

2.9

 

 

71

27.1

8.7

11.6

14.4

16.4

2.9

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

875

0.97

 

0.98

HIGH

1125

1.03

 

1.02

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

890

30000

 

14.00

12.00

 

 

 

 

 

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

4YCY4024A1 AT 800 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

22.9

19.1

21.4

22.9

22.9

1.8

85

63

23.9

15.6

17.9

20.2

21.8

1.8

67

25.8

12.3

14.7

17.0

18.6

1.9

 

 

71

27.8

9.1

11.5

13.8

15.3

1.9

 

59

20.9

18.2

20.5

20.9

20.9

2.0

95

63

21.8

14.7

17.0

19.3

20.9

2.0

67

23.5

11.5

13.8

16.1

17.7

2.0

 

 

71

25.3

8.3

10.6

12.9

14.5

2.0

 

59

18.8

17.3

18.8

18.8

18.8

2.1

105

63

19.6

13.8

16.1

18.5

19.6

2.1

67

21.1

10.6

12.9

15.3

16.8

2.2

 

 

71

22.8

7.4

9.7

12.1

13.6

2.2

 

59

16.7

16.4

16.7

16.7

16.7

2.3

115

63

17.5

13.0

15.3

17.5

17.5

2.3

67

18.8

9.8

12.1

14.4

16.0

2.3

 

 

71

20.3

6.6

8.9

11.2

12.8

2.3

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

700

0.97

 

0.98

HIGH

900

1.03

 

1.02

 

 

 

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

790

23400

 

14.00

11.60

 

 

 

 

 

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

4YCY4036A1/3 AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

34.5

28.8

32.4

34.5

34.5

2.7

85

63

36.0

23.4

27.0

30.5

32.9

2.7

67

38.8

18.5

22.0

25.6

27.9

2.8

 

 

71

41.9

13.5

17.1

20.6

23.0

2.8

 

59

32.0

27.6

31.2

32.0

32.0

3.0

95

63

33.4

22.3

25.9

29.4

31.8

3.1

67

35.9

17.4

20.9

24.5

26.9

3.1

 

 

71

38.8

12.4

16.0

19.6

21.9

3.1

 

59

29.5

26.5

29.5

29.5

29.5

3.3

105

63

30.7

21.2

24.8

28.4

30.7

3.4

67

33.1

16.3

19.9

23.4

25.8

3.4

 

 

71

35.7

11.4

15.0

18.5

20.9

3.4

 

59

26.9

25.4

26.9

26.9

26.9

3.6

115

63

28.1

20.2

23.7

27.3

28.1

3.7

67

30.2

15.3

18.8

22.4

24.8

3.7

 

 

71

32.7

10.4

13.9

17.5

19.9

3.7

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

1050

0.97

 

0.98

HIGH

1350

1.03

 

1.02

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

1210

36000

 

14.20

11.60

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

9

Page 9
Image 9
Trane 4YCY4024A, 4YCY4060A manual Performance Data Cooling