Escort EJ-CR-MEM USER GUIDE Powering & Charging the ChartReader, Power Failure, Meaning, Action

Models: EJ-CR-II MN-CR-MEM EI-CR-MEM EJ-CR-MEM EA-CR

1 16
Download 16 pages 11.84 Kb
Page 10
Image 10
USER GUIDE

USER GUIDE

Power FailureOverview of Power Indicator ModesMeaning Powering & Charging the ChartReader

The ChartReader contains an internal NiCad battery which typically, when fully charged, can provide power for about 1 hour of continuous printing.

To charge the NiCad battery, plug a 12V @ 1A supply into the DC connector located at the rear of the case. The plug needs to be a 2.1mm DC plug with negative on the inner connection.

(An adapter of lesser current rating (i.e. say 0.7 amp) can be used but this will increase the time it takes to fully charge the battery.) A 12V car cigarette lighter adapter can also be used.

When connected to a suitable power supply, the ChartReader will indicate that the battery is being charged by flashing the ON light.

The battery will normally take up to 2 hours to fully charge with 90% of the charge being attained within the first hour. The charger can be left permanently plugged in without damage to the ChartReader or battery.

Sometimes the battery will not take on a fast charge and the ON light will stop flashing well before 1 hour is elapsed. In this case the ChartReader will continue to charge the battery in a “trickle charge mode” and may take up to 18 hours to fully charge a battery.

Note: It is highly advised that the battery is fully exhausted before recharge to maximise life and capacity of the battery.

Note that because the ChartReader uses an intelligent charge technique, it cannot be turned off when external power is applied (i.e. a charger is connected). As soon as the external power supply is plugged into an inactive ChartReader, it will automatically turn on to maintain the charging of the battery.

Power Failure

The battery will typically exhaust itself during printing as this is the most energy consuming activity. When the battery is becoming exhausted, the ON indicator will rapidly flash and a beep will be sounded. If this occurs during printing (the most likely time) the printing will pause until either the battery voltage rises or a charger is plugged in.

To continue using the ChartReader, plug in an external power source. As long as the printing was not aborted it will automatically continue once a suitable external power supply is attached.

Overview of Power Indicator Modes

Action

Meaning

ON Indicator slowly flashing with charger

Charge in progress.

plugged in.

 

ON Indicator permanently on with charger

Fast Charge completed. Battery trickle charged.

plugged in.

 

ON Indicator flashing rapidly with beeping.

Battery nearly exhausted.

ON Indicator not on

ChartReader inactive (turned off).

!The NiCad battery is not included in the warranty.