Installer’s Guide
TABLE 12
GAS FLOW IN CUBIC FEET PER HOUR
2 CUBIC FOOT DIAL
SEC. | FLOW | SEC. | FLOW | SEC. | FLOW | SEC. | FLOW |
8 | 900 | 29 | 248 | 50 | 144 | 82 | 88 |
9 | 800 | 30 | 240 | 51 | 141 | 84 | 86 |
10 | 720 | 31 | 232 | 52 | 138 | 86 | 84 |
11 | 655 | 32 | 225 | 53 | 136 | 88 | 82 |
12 | 600 | 33 | 218 | 54 | 133 | 90 | 80 |
13 | 555 | 34 | 212 | 55 | 131 | 92 | 78 |
14 | 514 | 35 | 206 | 56 | 129 | 94 | 76 |
15 | 480 | 36 | 200 | 57 | 126 | 96 | 75 |
16 | 450 | 37 | 195 | 58 | 124 | 98 | 73 |
17 | 424 | 38 | 189 | 59 | 122 | 100 | 72 |
18 | 400 | 39 | 185 | 60 | 120 | 104 | 69 |
19 | 379 | 40 | 180 | 62 | 116 | 108 | 67 |
20 | 360 | 41 | 176 | 64 | 112 | 112 | 64 |
21 | 343 | 42 | 172 | 66 | 109 | 116 | 62 |
22 | 327 | 43 | 167 | 68 | 106 | 120 | 60 |
23 | 313 | 44 | 164 | 70 | 103 | 124 | 58 |
24 | 300 | 45 | 160 | 72 | 100 | 128 | 56 |
25 | 288 | 46 | 157 | 74 | 97 | 132 | 54 |
26 | 277 | 47 | 153 | 76 | 95 | 136 | 53 |
27 | 267 | 48 | 150 | 78 | 92 | 140 | 51 |
28 | 257 | 49 | 147 | 80 | 90 | 144 | 50 |
g | Outlet Pressure Boss | Regulator | |
Adjustment | |||
| |||
Inlet Pressure |
|
| |
Boss (opt.) | On/Off Switch |
| |
|
| ||
|
|
h | On/Off Switch |
| |
22 |
|
|
|
|
|
| TABLE 13 |
|
|
|
|
| |||
Orifice |
|
|
| ALTITUDE ABOVE SEA LEVEL |
| ||||||||
Twist Drill |
|
|
|
| |||||||||
Size If |
| and Orifice Required At Other Elevations |
| ||||||||||
Installed |
|
| |||||||||||
At Sea |
|
|
|
|
|
|
|
|
|
|
|
| |
Level |
|
|
|
|
|
|
|
|
|
|
|
| |
2000 | 3000 | 4000 | 5000 | 6000 | 7000 | 8000 | 9000 | 10000 | |||||
| |||||||||||||
42 | 42 |
| 43 |
| 43 | 43 | 44 | 44 | 45 | 46 |
| 47 | |
43 | 44 |
| 44 |
| 44 | 45 | 45 | 46 | 47 | 47 |
| 48 | |
44 | 45 |
| 45 |
| 45 | 46 | 47 | 47 | 48 | 48 |
| 50 | |
45 | 46 |
| 47 |
| 47 | 47 | 48 | 48 | 49 | 49 |
| 50 | |
46 | 47 |
| 47 |
| 47 | 48 | 48 | 49 | 49 | 50 |
| 51 | |
47 | 48 |
| 48 |
| 49 | 49 | 49 | 50 | 50 | 51 |
| 52 | |
54 | 54 |
| 55 |
| 55 | 55 | 55 | 55 | 56 | 56 |
| 56 | |
55 | 55 |
| 55 |
| 55 | 56 | 56 | 56 | 56 | 56 |
| 57 | |
56 | 56 |
| 56 |
| 57 | 57 | 57 | 58 | 59 | 59 |
| 60 | |
57 | 58 |
| 59 |
| 59 | 60 | 60 | 61 | 62 | 63 |
| 63 | |
58 | 59 |
| 60 |
| 60 | 61 | 62 | 62 | 63 | 63 |
| 64 |
From National Fuel Gas Code - Table
LIGHTING INSTRUCTIONS
▲! WARNING
DO NOT attempt to manually light the burner.
Failure to follow this warning could result in property damage, personal injury or death.
Lighting instructions appear on each unit. Each installation must be checked out at the time of initial start up to insure proper operation of all components. Check out should include putting the unit through one complete cycle as outlined below.
Turn on the main electrical supply and set the thermo- stat above the indicated temperature. The ignitor will automatically heat, then the gas valve is energized to permit the flow of gas to the burners. After ignition and flame is established, the flame control module monitors the flame and supplies power to the gas valve until the thermostat is satisfied.
TO SHUT OFF
For complete shutdown: Move the control switch on the main gas valve to the “OFF” position (See Figures 25 and 26). Disconnect the electrical supply to the unit.
▲! CAUTION
If this is done during the cold weather months, provi- sions must be taken to prevent
Failure to follow this warning could result in property damage.
Whenever your house is to be vacant, arrange to have someone inspect your house for proper tem- perature. This is very important in below freez- ing weather. If for any reason your furnace should fail to operate damage could result, such as frozen water pipes.