Image 5
Cable Specifications -- Continued

CETTF10xx-200

Cable Specifications -- Continued

Copper Cable

Category 3: (minimum requirement)

 

Gauge

24 to 22 AWG

Attenuation

11.5 dB/100m @ 5-10 MHz

Maximum Cable Distance

100 meters

Category 5: (recommended)

 

Gauge

24 to 22 AWG

Attenuation

22.0 dB /100m @ 100 MHz

Maximum Cable Distance

100 meters

Straight-through OR twisted-pair cable may be used.

Shielded twisted-pair OR unshielded twisted-pair may be used.

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network.

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

Do not use flat or silver satin wire.

 

Straight-Through Cable

 

Crossover Cable

 

 

Twisted Pair #1

 

 

1

 

 

1

 

Twisted Pair #1

1

 

 

1

 

 

 

2

 

 

 

2

 

2

 

 

2

 

 

 

 

 

 

 

 

 

 

Twisted Pair #2

 

 

3

 

 

3

 

Twisted Pair #2

3

 

 

3

 

 

 

6

 

 

 

6

 

6

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Specifications

For use with Transition Networks Model CETTF10xx-200 or equivalent.

Standards

IEEE 802.3™

 

Data Rate

10 Mb/s

 

Dimensions

3.4" x 0.86" x 5.0" (86 x 22 x 127 mm)

Weight

3 oz (91 g) (approximate)

Power Consumption

2.3 watts

 

MTBF

408,231 hours (MIL217F2 V5.0) (MIL-HDBK-217F)

 

1,412,845 hours (Bellcore7 V5.0)

Environment

Tmra*:

0 to 60°C (32 to 140°F )

 

Storage Temp:

-20 to 85°C (-4 to 185°F)

 

Humidity:

10 to 90%, non condensing

 

Altitude:

0 to 10,000 feet

Warranty

Lifetime

 

*Manufacturer’s rated ambient temperature: Tmra range for this media converter depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem™ chassis in which this media converter will be installed.

The information contained in this user’s guide is subject to change. For the most up-to-date version, see the user’s guide on line at: www.transition.com.

8

24-hour Technical Support: 1-800-260-1312-- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

9

Page 5
Image 5
Transition Networks CETTF10XX-200 Cable Specifications -- Continued, Technical Specifications, Copper Cable, CETTF10xx-200