CABLE SPECIFICATIONS (continued)

Twisted-Pair Copper Cable

Twisted pair connection requires two active pairs. The two active pairs in a T1/E1 network are pins 1 & 2 and pins 4 & 5. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.

Category 3 or better twisted-pair copper wire is required. Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used.

T1:

Gauge

24 to 22 AWG

Attenuation

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

100 ±10%

E1:

Gauge

24 to 22 AWG

Attenuation

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

120 ±10%

Dry-Contact Relay

RJ-45 dry-contact relay opens if power, signal detect/copper or signal detect/fiber are lost.

Operational rating on pins 3 and 6: 0-30VDC maximum 1A

Relay

3RJ-45

6

Switch-Selectable Configurations

T1 COPPER RJ-45

Configured as either "long haul" or “short haul” on 100 ohm cable, with a variety of selectable distance settings.

E1 COPPER RJ-45

Configured as either "long haul" or “short haul” on 120 ohm cable.

STRAIGHT-THROUGH/CROSSOVER RJ-45

Allows straight-through cable to be used where crossover-configuration cable is required.

Switch-Selectable Functions

LOOPBACK TEST FUNCTION

A loopback switch facilitates installation and network debug procedures. The path for the CSDTF10xx loopback is shown:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TP

 

 

 

 

Fiber

 

 

 

 

 

 

 

 

TP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSMIT ALL ONES FUNCTION

A selectable Transmit All Ones switch on the fiber interface and on the twisted-pair interface allows for insertion of an “all ones” pattern on that interface when signal detect is lost, which creates an alarm condition at the equipment connected to the interface.

Page 3
Image 3
Transition Networks CSDTF1022-100 instruction manual Cable Specifications, Twisted-Pair Copper Cable, Dry-Contact Relay