INSTALLATION

CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting switch and when installing Media Converter Slide-in- Module in the Media Conversion Center. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in- Module.

Set Loopback Test Switch

NOTE: The Loopback Test switch, located on Media Converter Slide-in-

Module front panel, allows the network administrator

 

 

 

 

 

 

to enable a loopback test for installation and network

 

 

Loop

debug procedures.

 

 

 

 

 

 

Use small flatblade screwdriver or similar device to set recessed switches. Refer to drawing for switch locations.

Set 3-Position Jumper

NOTE: Jumper is located on Media Converter Slide-in-Module circuit board.

CABLE SPECIFICATIONS

Fiber Cable

Bit error rate:

10-9

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

 

85 / 125 µm multimode fiber

 

50 / 125 µm multimode fiber

CSDTF1011-100

850 nM

 

Fiber Optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber Optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical Maximum Cable Distance*:

2 kilometers

 

CSDTF1013-100

850 nM

 

Fiber-optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical Maximum Cable Distance*:

2 kilometers

 

Use small needle-nosed pliers or similar device to set jumper. Refer to drawing for jumper positions.

HARDWARE Converter mode is determined by 4-position switch settings below.

SOFTWARE Converter mode is determined by most- recently-saved on-board microprocessor settings.

Set MDI/MDI-X Switch

H S

HARDWARE MODE

H S

SOFTWARE MODE

SINGLEMODE

 

 

Fiber Optic Cable Recommended:

9 µm singlemode fiber

CSDTF1012-100

1300 nM

 

Fiber-optic Transmitter Power:

min: -21.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

8 kilometers

 

CSDTF1014-100

1300 nM

 

Fiber-optic Transmitter Power:

min: -21.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -27.0 dBm

max: -14.0 dBm

NOTE: The MDI/MDI-X switch, located on Media Converter Slide-in-Module circuit board, allows the network administrator to use straight-through cable in installations where crossover-configuration cable is required.

Use small flatblade screwdriver or similar device to set recessed switches. Refer to drawing for switch settings.

Typical Maximum Cable Distance*:

8 kilometers

 

CSDTF1015-100 (long haul)

1300 nM

 

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -27.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

15 kilometers

 

CSDTF1022-100 (long haul)

1300 nM

 

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

MDI

Twisted

 

1

RTIP

 

TTIP

Twisted

Pair

#1

 

2

RRING

 

TRING

Pair

#1

 

 

Twisted

 

4

TTIP

 

RTIP

Twisted

Pair

#2

 

5

TRING

 

RRING

Pair

#2

 

 

 

 

 

 

 

 

 

 

 

Connectors for unlike devices

Set 8-Position Switch

 

 

MDI-X

1

 

 

 

 

 

RTIP

 

 

 

RTIP

 

 

2

RRING

 

 

 

RRING

 

 

4

TTIP

 

 

 

TTIP

 

 

5

TRING

 

 

 

TRING

 

 

 

 

 

 

 

 

Connectors for like devices

Typical Maximum Cable Distance*:

15 kilometers

*Actual distance dependent upon physical characteristics of network installation.

NOTE: The eight-position switch, located on Media Converter Slide-in- Module circuit board, allows the network administrator to configure the media converter for network conditions.

Use small flatblade screwdriver or similar device to set recessed switches for site installation. Refer to drawings at right for eight-position switch settings.

Page 4
Image 4
Transition Networks CSDTF1022-100 instruction manual Installation, Cable Specifications