J/FE-CF-03

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications.

Fiber cable

Bit Error Rate:

<10-9

 

Singlemode fiber (recommended):

9 μm

 

Multimode fiber (recommended):

62.5/125 μm

 

Multimode fiber (optional):

100/140, 85/140, 50/125 μm

J/FE-CF-03

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

 

J/FE-CF-03(SC)

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

 

J/FE-CF-03(SM) & (LH)

1300 nm singlemode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

 

J/FE-CF-03-100

1310 nm (TX)/1550 nm (RX) simplex

J/FE-CF-03-101

1550 nm (TX)/1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

 

Copper cable

 

 

Category 5:

 

 

Gauge:

24 to 22 AWG

 

Attenuation:

22.0 dB/100m @ 100 MHz

Maximum Cable Distance:

100 meters

 

Straight-Through or Crossover cable may be used.

Shielded Twisted-Pair (STP) or Unshielded Twisted-Pair (UTP) may be used.

Pins 1&2 and 3&6 are the two active pairs in an Ethernet™ network .

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

• Do not use flat or silver satin wire.

Technical Specifications

For use with Transition Networks Model J/FE-CF-03 or equivalent

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.

Standards:

IEEE 802.3™

Data Rate:

100 Mb/s

Case Dimensions:

3.9" x 3.0" x 1.0" (100mm x 76mm x 25mm)

Shipping Weight:

2 pounds (0.9 kilograms)

Power Consumption:

2.8 watts, 200 mA @ 13.9 VDC

Power Supply DC Output:

12 VDC, 0.4 A (minimum)

 

minimum output regulation: 5%

 

Connector: 2.1mm barrel, center pin positive

MTBF*

48,135 hours

 

(MIL217F2 V5.0) (MIL-HDBK-217F)

 

128,553 hours (Bellcore7 V5.0)

Environment:

 

Tmra**:

0 to 60°C (32 to 140°F)

Storage Temp:

-20 to 85°C (-4 to 185°F)

Humidity:

5-95%, non-condensing

Altitude:

0-10,000 feet

Warranty:

Lifetime

**Manufacturer’s rated ambient temperature.

WARNING: Visible and invisible laser radiation when open. Do not stare into the beam or view the beam directly with optical instruments. Failure to observe this warning could result in an eye injury or blindness.

WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.

CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra- building (inside plant) link segments that are not subject to lightening transients or power faults. Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter- building (outside plant) link segments that are subject to lightening transients or power faults. Failure to observe this caution could result in damage to equipment.

*MTBF is estimated using the predictability method. This method is based on MIL- 217F at 25°C ambient temperature, typical enclosure heat rise of 10°C, and nominal operating conditions and parameters. Installation and configuration specific MTBF estimates are available upon request. Contact Technical Support.

6

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

7

Page 4
Image 4
Transition Networks J/FE-CF-03 Cable Specifications, Technical Specifications, Fiber cable, Copper cable, Category