Transition Networks M/GE-PSW-SX-01 Cable Specifications, Technical Specifications, Fiber cable

Models: M/GE-PSW-LX-01 M/GE-PSW-SX-01

1 9
Download 9 pages 31.54 Kb
Page 6
Image 6
Cable Specifications

M/GE-PSW-xX-01

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications.

Technical Specifications

For use with Transition Networks Model M/GE-PSW-xX-01 converters.

Fiber cable

Bit Error Rate:

single mode fiber (recommended): Multimode fiber (recommended): Multimode fiber (optional):

M/GE-PSW-SX-01 (SC)

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

M/GE-PSW-LX-01 (SC)

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

<10-9

9μm 62.5/125 μm

100/140, 85/140, 50/125 μm

850nm multimode

 

min: -10.0 dBm

max: -4.0 dBm

min: -17.0 dBm

max: -0.0 dBm

7.0 dB

 

1310 nm single mode

 

min: -9.5 dBm

max: -3.0 dBm

min: -20.0 dBm

max: -3.0 dBm

10.5 dB

 

Standards:

IEEE 802.3-2000

Data rate:

10 Mb/s, 100 Mb/s, 1000 Mb/s

Dimensions:

1.8"W x 3.35"D x 0.85"H (45.7 x 85.1 x 21.6 mm)

Weight:

3.15 oz. (127.5 g) approximately

MTBF*:

24,466 hours (MIL217F2 V5.0) (MIL-HDBD-217F)

 

100,130 hours (Bellcore7 V5.0)

Packet size:

Memory: 9256K bytes

MAC addresses:

8K

Maximum packet size:

1632 bytes, untagged

 

1628 bytes, tagged

Power sources:

Unit will accept - 5 to 28 VDC

 

Barrel connector - Wall Mount AC Adapter

 

(400mA at 12VDC)(The external power supply provided

The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.

Copper cable

Category 5 and Category 5e: minimum requirement

Gauge

24 to 22 AWG

Attenuation

22.0 dB /100m @ 100 MHz

Maximum Cable Distance

100 meters

Straight-through or crossover twisted-pair cable may be used.

Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network.

All four pairs are used in a gigabit Ethernet network.

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

• Do not use flat or silver satin wire.

 

with this product is UL listed by the power supply’s

 

manufacturer.)

 

Power consumption:

262mA @ 12VDC, 3.15 watts

Environment:

Tmra**:

0°C to 50°C (32°F to 122°F )

 

Storage Temp:

-25°C to 65°C (-13°F to 149°F)

 

Humidity:

5% to 95%, non-condensing

 

Altitude:

0 to 10,000 feet

Warranty:

Lifetime

 

*MTBF is estimated using the predictability method. This method is based on MIL- 217F at 25°C ambient temperature, typical enclosure heat rise of 10°C with nominal operating conditions and parameters. Installation and configuration specific MTBF estimates are available upon request. Contact Technical Support.

**Manufacturer’s rated ambient temperature.

Twisted Pair #1

Twisted Pair #2

Twisted Pair #1

Twisted Pair #2

Twisted Pair #3

Twisted Pair #4

S traight Through Cable

 

Cross over Cable

 

1

1

Twisted Pair #1

1

1

2

2

2

2

 

3

3

Twisted Pair #2

3

3

6

6

6

6

 

CAT5e Gigbit Ethernet

Straight-Through Cable

11

22

33

44

55

66

77

88

CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra- building (inside plant) link segments that are not subject to lightening transients or power faults. Copper-based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter- building (outside plant) link segments that are subject to lightening transients or power faults. Failure to observe this caution could result in damage to equipment.

10

Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

11

Page 6
Image 6
Transition Networks M/GE-PSW-SX-01 specifications Cable Specifications, Technical Specifications, Fiber cable, Copper cable