Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Technical Specifications
For use with Transition Networks Model
Fiber cable
Bit Error Rate:
single mode fiber (recommended): Multimode fiber (recommended): Multimode fiber (optional):
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Link Budget:
Link Budget:
9μm 62.5/125 μm
100/140, 85/140, 50/125 μm
850nm multimode |
|
min: | max: |
min: | max: |
7.0 dB |
|
1310 nm single mode |
|
min: | max: |
min: | max: |
10.5 dB |
|
Standards: | IEEE |
Data rate: | 10 Mb/s, 100 Mb/s, 1000 Mb/s |
Dimensions: | 1.8"W x 3.35"D x 0.85"H (45.7 x 85.1 x 21.6 mm) |
Weight: | 3.15 oz. (127.5 g) approximately |
MTBF*: | 24,466 hours (MIL217F2 V5.0) |
| 100,130 hours (Bellcore7 V5.0) |
Packet size: | Memory: 9256K bytes |
MAC addresses: | 8K |
Maximum packet size: | 1632 bytes, untagged |
| 1628 bytes, tagged |
Power sources: | Unit will accept - 5 to 28 VDC |
| Barrel connector - Wall Mount AC Adapter |
| (400mA at 12VDC)(The external power supply provided |
The fiber optic transmitters on this device meet Class I Laser safety requirements per
Copper cable
Category 5 and Category 5e: minimum requirement
Gauge | 24 to 22 AWG |
Attenuation | 22.0 dB /100m @ 100 MHz |
Maximum Cable Distance | 100 meters |
•
•Shielded (STP) or unshielded (UTP)
•Pins 1&2 and 3&6 are the two active pairs in an Ethernet network.
•All four pairs are used in a gigabit Ethernet network.
•Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
| with this product is UL listed by the power supply’s | |
| manufacturer.) |
|
Power consumption: | 262mA @ 12VDC, 3.15 watts | |
Environment: | Tmra**: | 0°C to 50°C (32°F to 122°F ) |
| Storage Temp: | |
| Humidity: | 5% to 95%, |
| Altitude: | 0 to 10,000 feet |
Warranty: | Lifetime |
|
*MTBF is estimated using the predictability method. This method is based on MIL- 217F at 25°C ambient temperature, typical enclosure heat rise of 10°C with nominal operating conditions and parameters. Installation and configuration specific MTBF estimates are available upon request. Contact Technical Support.
**Manufacturer’s rated ambient temperature.
Twisted Pair #1
Twisted Pair #2
Twisted Pair #1
Twisted Pair #2
Twisted Pair #3
Twisted Pair #4
S traight Through Cable |
| Cross over Cable |
| ||
1 | 1 | Twisted Pair #1 | 1 | 1 | |
2 | 2 | 2 | 2 | ||
| |||||
3 | 3 | Twisted Pair #2 | 3 | 3 | |
6 | 6 | 6 | 6 | ||
|
CAT5e Gigbit Ethernet
11
22
33
44
55
66
77
88
CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra- building (inside plant) link segments that are not subject to lightening transients or power faults.
10 | Tech Support: | techsupport@transition.com | 11 |