100BASE-TX Cable and Connector Specifications

CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.

Compliance Information

UL Listed

C-UL Listed (Canada)

CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.

100BASE-TX Cable and Connector Specifications

The physical characteristics of the 100BASE-TX cable must meet or exceed IEEE 802.3u 100BASE-TX specifications.

100BASE-TX CABLE SPECIFICATIONS

Category 5 wire or better is required. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

Category 5:

 

Gauge

24 to 22 AWG

Attenuation

20 dB/1000’ @ 10 MHz

Impedance

100 Ω ±10% @ 10 MHz

Maximum Cable Distance:

100 meters (330 feet)

100BASE-TX CONNECTOR CHARACTERISTICS:

The 100BASE-TX connectors are standard RJ-45 connectors with standard pinning.

The two active pairs in a 100BASE-TX network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins. 100BASE-TX cable for unlike devices (such as hub to terminal device) must be configured as straight through; 100BASE-TX cable for like devices (such as hub to hub or terminal device to terminal device) must be configured as crossover.

European Regulations

Warning

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Straight Through Cable

Twisted

Pair #1

Twisted

Pair #2

Crossover Cable

Twisted

Pair #1

Twisted

Pair #2

Copyright Restrictions

© 1996, 1997 TRANSITION Networks.

All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.

Trademark Notice

All registered trademarks and trademarks are the property of their respective owners.

Connectors for unlike devices

Connectors for like devices

NOTE: MDI/MDI-X connectors on hubs allow straight-through cable to be used in a crossover configuration for hub to hub connection.