4. OPERATION | 2. SITE CONSIDERATIONS | |
The StackMaster TX12 normally requires no intervention beyond | The site for the StackMaster TX12 hub must provide: | |
occasionally monitoring the Power and Status LEDs. | • AC power outlet for each hub | |
| • | Adequate ventilation |
| • | Standard environmental conditions |
| • Isolation from electrical noise, including radio transmitters | |
|
| and broadband amplifiers, motors, high power electrical |
|
| lines, or fluorescent light fixtures. |
| Additionally: | |
| • The twisted pair cables should not run in the same conduit | |
|
| with power line cables |
| • Phone lines should be separated from data cables | |
| • Flat or “silver satin” wires should not be used. | |
| And: |
|
| • Since the StackMaster TX12 functions as an Ethernet | |
|
| Repeater, the entire installation should comply with the IEEE |
|
| Ethernet 802.3 specification. |
Status LEDs
Status LEDs are located at the front of the StackMaster TX12.
POWER | Illuminated green: Hub powered ON. |
UTILIZATION | Iilluminated green 1%, 8%, 16%, 32%, or 64% |
| network activity |
COLLISION | Illuminated amber: Collision detected during |
| data transmission on ANY port. |
LINK/ACTIVITY | Illuminated green: Port link established. |
| Flashing green: Data being received. |
ERROR | Flashing yellow: Error detected on port. OR |
| port partitioned and isolated. |
11 | StackMaster™ TX12 | 4 |