Traulsen RAC3T owner manual IX. TROUBLESHOOTING GUIDE cont’d, Problem, Possible Cause/Remedy

Models: RAC3T

1 12
Download 12 pages 43.19 Kb
Page 8
Image 8

IX. TROUBLESHOOTING GUIDE (cont’d)

 

PROBLEM

 

POSSIBLE CAUSE/REMEDY

6. Condensing unit operates for prolonged

1.

Shortage Of Refrigerant - Fix Leak, Add Charge

 

periods or continuously.

2.

Control Contacts Stock or Frozen Closed - Clean Contacts or

 

 

 

Replace Control

 

 

3.

Excessive Heat Load Placed Into Cabinet - Allow Unit

 

 

 

Sufficient Time For Removal Of Latent Heat

 

 

4.

Prolonged or Too Frequent Door Openings - Plan or

 

 

 

Organize Schedule To Correct Condition

 

 

5.

Evaporator Coil Iced - Defrost

 

 

6.

Restriction In Refrigeration System - Determine Locations &

 

 

 

Remove

 

 

7.

Dirty Condenser - Clean Condenser

 

 

8.

Filter Dirty - Clean or Replace

7.

Start capacitor open or shorted or blown.

1.

Relay Contacts Not Opening Properly - Clean Contacts or

 

 

 

Replace Relay If Necessary

 

 

2.

Prolonged Operation On Start Cycle Due To:

 

 

 

a) Low Voltage To Unit - Determine Reason & Correct

 

 

 

b) Improper Relay - Replace

 

 

 

c) Starting Load Too High - Correct By Using Pump Down

 

 

 

Arrangement If Necessary

 

 

3.

Excessive Short Cycling - Determine Reason For Short

 

 

 

Cycling (see #5 above) And Correct

 

 

4.

Improper Capacitor - Determine Correct Size

8.

Run capacitor open, shorted or blown.

1.

Improper Capacitor - Determine Correct Size & Replace

 

 

2.

Excessively High Line Voltage (110% of rated max) -

 

 

 

Determine Reason & Correct

9.

Relay defective or burned out.

1.

Incorrect Relay - Check & Replace

 

 

2.

Incorrect Mounting Angle - Remount Relay In Correct

 

 

 

Position

 

 

3.

Line Voltage Too High or Too Low - Determine Reason &

 

 

 

Correct

 

 

4.

Excessive Short Cycling - Determine Reason (see #5 above)

 

 

 

& Correct

 

 

5.

Relay Being Influenced By Loose Vibrating Mounting -

 

 

 

Remount Rigidly

 

 

6.

Incorrect Run Capacitor - Replace With Proper Capacitor

10. Product zone temperature too high.

1.

Control Setting Too High - Reset Control

 

 

2.

Inadequate Air Circulation - Rearrange Product Load To

 

 

 

Improve Air Circulation

11. Suction line frosted or sweating.

1.

Overcharge of refrigerant - Correct Charge

 

 

2.

Evaporator Fan Not Running - Determine Reason & Correct

12. Liquid line frosted or sweating.

1.

Restriction In Dehydrator or Strainer - Replace Part

 

 

2.

Liquid Shut-Off (king valve) Partially Closed - Open Valve

 

 

 

Fully

13. Noisy condensing unit.

1.

Loose Parts or Mounting - Find & Tighten

 

 

2.

Tubing Rattle - Reform To Free Of Contact

 

 

3.

Bent Fan Blade Causing Vibration - Replace Blade

 

 

4.

Fan Motor Bearing Worn - Replace Motor

-7-

Page 8
Image 8