Traulsen TD048HT & TD078HT manual End of Day continued, Routine Maintenance, IV. Completion

Models: TD048HT & TD078HT

1 5
Download 5 pages 46.46 Kb
Page 4
Image 4
End of Day (continued)

5 TRAULSEN TD048HT & TD078HT TRAINING GUIDE

6

 

 

 

 

 

 

End of Day (continued)

Routine Maintenance

 

 

 

 

 

 

 

 

II.Cleaning the Cabinet (required after each use)

1.Open the compressor access door.

2.Locate drain hose over a floor drain or large bucket (see fig. 1).

3.Open drain valve by turning clockwise.

4.Spray out the display well and sanitize thoroughly. Allow all water to run out the drain.

4. Close the drain valve by turning counter-clockwise.

fig. 1

Close the compressor access door.

 

 

5. Wipe out the refrigerated area behind the doors

 

using a non-abrasive, non-clorinated, stainless steel

 

safe cleanser. Leave the door(s) open until next

 

use.

WARNING!

 

 

 

Spraying water inside the refrigerated area behind the

 

doors may cause equipment damage and/or injury.

III.Cleaning the Fan Blade(s) (required after each use)

1.Throughly clean fan post using alcohol or mineral spirits and a clean, lint-free cloth.

2.Clean the bearing inside of the fan blade assembly using a cotton swap moistened with alcohol or mineral spirits (see fig. 1).

3.Place a few drops of the lubricant supplied by Traulsen into the fan blade assembly rear.

4.Replace the fan blade assembly on the post.

fig. 1

fig. 2

IV. Completion

1. Reassemble cabinet by reversing steps 1 thru 9 on page 4.

Care of the Display Canopy (required as needed)

1.Disconnect power supply.

2.Remove the screws securing canopy brackets (see fig. 1).

3.Lift curved canopy section(s) towards front, out of

mounting bar bracket, and up and away from the cabinet (see fig. 2).

 

NOTE

 

 

On 78” units the two canopy sections are

fig. 1

 

 

 

connected by a plastic H-Channel.

 

4.

Lift out canopy side pieces.

 

5.

Wash all canopy parts in hot, soapy water.

 

WARNING!

Use of ammonia or ammonia containing cleaners, such as windex, will blur and/or craze the plexiglass canopy.

6.

Allow to air dry and wipe away any water spots using

fig. 2

 

a clean, dry cloth.

 

 

7.

Reassemble by reversing steps 1 thru 4.

 

Cleaning the Condenser (required approx. every 90-days)

Cleaning the condenser is critical to insuring proper performance and long compressor life.

1.Disconnect power supply.

2.Open the compressor access door.

3.Vacuum or brush coil fins clear of any dust or debris present.

4.Close the compressor access door.

5. Restore power.

fig. 1

 

fig. 2

NOTE: Leave door(s) open until next use and power is restored.

Page 4
Image 4
Traulsen TD048HT & TD078HT End of Day continued, Routine Maintenance, II.Cleaning the Cabinet required after each use