5 TRAULSEN TD048HT & TD078HT TRAINING GUIDE | 6 | ||||
|
|
|
| ||
|
| End of Day (continued) | Routine Maintenance |
|
|
|
|
|
|
|
|
II.Cleaning the Cabinet (required after each use)
1.Open the compressor access door.
2.Locate drain hose over a floor drain or large bucket (see fig. 1).
3.Open drain valve by turning clockwise.
4.Spray out the display well and sanitize thoroughly. Allow all water to run out the drain.
4. Close the drain valve by turning
fig. 1 | Close the compressor access door. | |
| ||
| 5. Wipe out the refrigerated area behind the doors | |
| using a | |
| safe cleanser. Leave the door(s) open until next | |
| use. | WARNING! |
|
| |
| Spraying water inside the refrigerated area behind the | |
| doors may cause equipment damage and/or injury. |
III.Cleaning the Fan Blade(s) (required after each use)
1.Throughly clean fan post using alcohol or mineral spirits and a clean,
2.Clean the bearing inside of the fan blade assembly using a cotton swap moistened with alcohol or mineral spirits (see fig. 1).
3.Place a few drops of the lubricant supplied by Traulsen into the fan blade assembly rear.
4.Replace the fan blade assembly on the post.
fig. 1
fig. 2
IV. Completion
1. Reassemble cabinet by reversing steps 1 thru 9 on page 4.
Care of the Display Canopy (required as needed)
1.Disconnect power supply.
2.Remove the screws securing canopy brackets (see fig. 1).
3.Lift curved canopy section(s) towards front, out of
mounting bar bracket, and up and away from the cabinet (see fig. 2).
| NOTE |
|
| On 78” units the two canopy sections are | fig. 1 |
|
| |
| connected by a plastic |
|
4. | Lift out canopy side pieces. |
|
5. | Wash all canopy parts in hot, soapy water. |
|
WARNING!
Use of ammonia or ammonia containing cleaners, such as windex, will blur and/or craze the plexiglass canopy.
6. | Allow to air dry and wipe away any water spots using | fig. 2 |
| a clean, dry cloth. | |
|
| |
7. | Reassemble by reversing steps 1 thru 4. |
|
Cleaning the Condenser (required approx. every
Cleaning the condenser is critical to insuring proper performance and long compressor life.
1.Disconnect power supply.
2.Open the compressor access door.
3.Vacuum or brush coil fins clear of any dust or debris present.
4.Close the compressor access door.
5. Restore power. | fig. 1 |
|
fig. 2