IV. OPERATION (cont’d) | IV. OPERATION (cont’d) |
When this condition exists the oven will sound an audible alarm by emitting a triple beep (three quick short beeps) every 2 seconds and it will flash the message “Err too Hot” on the display to alert nearby staff. The audible alarm may be temporarily canceled FOR 3 MINUTES by pushing ADJ/SET. After 3 minutes have expired the oven will begin beeping again. The error message on the display cannot be canceled. The proper action when this alarm is present is to turn the oven off and call for service.
IV. e - TESTING THE OVEN:
Before using the oven for the first time, verify that the oven oper- ates normally.
Check that the oven is connected to the correct power source.
Turn the oven ON at the power switch.
Use the controls to set the HOLDING TEMPERATURE to 1400F.
Check that the oven circulating fans are running.
Check that the heaters ON indicator is lit.
Check that the oven is warming to the displayed holding tem- perature.
NOTE: The cooling fans may not operate when the oven is first turned on. The cooling fans operate only when the thermostat to which they are connected requires it.
Set the TIME to 2 hours, Set the RETHERM TEMP to 2500, push the START BUTTON, check the interior rear of the oven cavity to determine that the oven is heating.
Push the ADJ/SET knob to cancel the cycle, set the TIME to 0, set the HOLD TEMP to 2500F, push the START BUTTON.
Check that the RETHERM TEMP display has been blanked and the HOLD TEMP display is lighted.
Check the interior rear of the oven to ensure that the oven is heating. If all the functions perform satisfactory, the oven is ready for operation.
IV. f - OPERATING THE OVEN:
Main Features
Quick cycle
Quick cycle
User programming of the 9 most used cycle parameters. Fast recall and cycle start of the
Very fast recall and cycle start of
Manual Setting Features
From the IDLE STATE (TIME is blinking) rotate the ADJ/ SET knob to adjust the retherm time. Press START to ac- cept the currently displayed settings and begin the cycle or press ADJ/SET to set the currently displayed time and advance to the RETHERM TEMP setting. RETHERM is blinking. Rotate the ADJ/SET knob to adjust the retherm temperature. Press START to begin the cycle or press ADJ/SET to set the retherm temperature and advance to the HOLD TEMP setting. HOLD is blinking. Rotate ADJ/SET to adjust the hold temperature. Press START to execute the cycle or press ADJ/SET to
From the IDLE STATE (Time Blinking) press and hold ADJ/SET for 3 seconds. TIME no longer blinks. The current temperature display TEMP displays
. After a cycle is started press ADJ/SET at any time to abort the cycle and return to idle.
Programming The
From the IDLE STATE (Time Blinking) press and hold ADJ/SET for 3 seconds. TIME no longer blinks. The current temperature display TEMP displays
Fast cycle Start Using
(see page 11 for Retherm & Holding Guide)