5

4

 

 

 

 

 

 

 

3

 

 

 

 

2

 

 

1

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

Refer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

CONTACTOR

 

 

HEATING

HEATING

HEATING

HEATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELEMENT

ELEMENT

ELEMENT

ELEMENT

 

 

 

to

 

 

DISTRIBUTION BLOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the

 

 

COOLING FAN

 

FUSE 3A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE 3A

 

 

 

 

 

 

160 OHM

 

BLOWER FAN

BLOWER FAN

BLOWER FAN

BLOWER FAN

 

 

 

wiring

 

 

 

 

 

 

 

 

 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

.1uF/600V

 

 

 

 

 

 

 

 

 

 

diagram

 

 

IN LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REAR VIEW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

below

VI.

 

L2

L1

 

 

 

 

HI - LIMIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING FAN 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for any service work performed by

WIRING DIAGRAM

 

 

 

 

 

 

 

 

 

 

 

 

TERMINAL BLOCK

TERMINAL BLOCK

 

 

 

 

-7-

IN LINE

IN LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING FAN 2

 

 

 

 

 

HEATER RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

3

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

#

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

YELLOW

START SWITCH

 

 

 

12VDC

# = .25" FASTON, 6 TOTAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

CONTACT PINS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

YELLOW

C

NO

NC

 

 

#

 

#

 

AMP 640252-1 or 770476-1

 

 

 

 

 

 

 

 

 

 

 

 

QTY = 4

 

 

 

 

 

 

 

 

 

 

1

3

2

 

 

 

 

 

 

QTY =

2

 

 

 

 

 

 

 

 

12V CLASS II

$

$

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COIL+ COIL-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$ = .125" FASTON, 2 TOTAL

 

 

 

 

 

 

 

 

 

K TYPE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOCOUPLE,

 

 

 

 

 

#

#

 

 

 

AMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2 3 4

 

 

 

 

 

 

 

GROUNDED

 

 

 

 

a

 

 

 

 

 

 

 

640250-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J4

1

2

3 4

 

 

 

 

 

T-

RED

 

 

 

 

 

 

qualified

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3

T+

YELLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

2

 

 

 

 

 

 

 

 

A

J1-1

J2-1

 

 

 

 

 

 

 

 

AMP

 

6 CONDUCTOR RIBBON

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

640250-2

 

SHAFT ENCODER

Traulsen & Company

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4401 Blue Mound Rd., Fort Worth, TX 76106

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8

 

 

 

Title

 

 

 

 

 

technician.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT-32 WIRING DIAGRAM, 208-240v, 10, 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size

Document Number

 

 

 

Rev

 

 

 

CONTROL AND DISPLAY BOARD

 

 

 

 

 

 

 

 

 

 

B

379-60486-00

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date:

Thursday, July 10, 2008

Sheet

1

of

12

 

 

5

4

 

 

 

 

 

 

 

3

 

 

 

 

2

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 8
Image 8
Traulsen TRT32R owner manual Wiring Diagram, Refer

TRT32, TRT32R specifications

The Traulsen TRT32R and TRT32 are premier reach-in refrigeration units designed to meet the demanding needs of commercial kitchens. Renowned for their durability and efficiency, these models are essential for any food service operation aiming to maintain high standards of temperature control and food safety.

One of the standout features of the Traulsen TRT32R and TRT32 is their robust construction. The exterior is made from heavy-duty stainless steel, which not only provides a sleek and professional appearance but also ensures long-lasting performance in a high-traffic environment. The interior, also constructed of stainless steel, enhances durability while facilitating easy cleaning, thus promoting hygiene in compliance with strict health codes.

These units boast impressive insulation with 2-inch thick foamed-in-place polyurethane, providing superior thermal efficiency. This design minimizes energy consumption and maintains consistent temperatures, crucial for preserving the freshness and safety of stored products. The units are equipped with high-performance refrigeration systems, ensuring rapid temperature recovery after door openings and maintaining temperatures between 32°F and 38°F.

In terms of technology, the Traulsen TRT32R and TRT32 feature microprocessor controls that allow for precise temperature adjustments. The digital display offers easy monitoring of internal temperatures, while the unit’s automatic defrost eliminates the hassle of manual defrosting, further enhancing efficiency.

Moreover, the adjustable shelving provides flexibility to accommodate various food storage needs, whether for bulk ingredients or ready-to-serve items. The heavy-duty casters grant excellent mobility, making it easy to reposition the unit for cleaning or storage.

Traulsen’s commitment to quality is evident through rigorous testing and their adherence to NSF and UL standards, ensuring reliable performance in even the busiest commercial settings.

Overall, the Traulsen TRT32R and TRT32 offer a perfect blend of functionality, durability, and efficiency. They are an excellent investment for any kitchen needing reliable refrigeration solutions, designed to stand the test of time while protecting food quality and safety.