X. TROUBLE SHOOTING GUIDE

FIND YOUR PROBLEM HERE

 

REMEDY

 

 

 

1.Condensing unit fails to start.

a.

Check if line has been disconnected.

 

b.

Check T-Stat setting and operation.

 

c.

Check switch behind louvers.

 

 

 

2. Condensing unit operates for

a.

Shortage of refrigerant, locate and repair

prolonged periods or continuously.

 

leak, evacuate and recharge per the

 

 

manufacturer’s requirements.

 

b.

Dirty condenser or filter. Clean properly.

 

c.

Are doors closing properly?

 

d.

Evaporator coil iced. Check defrost clock and

 

 

heating element.

 

e.

Check to see if there are any restrictions in

 

 

refrigeration system.

 

 

 

3. Food compartment is too warm.

a.

Thermostat setting too high, readjust

 

 

thermostat.

 

b.

Perhaps a large quantity of food has

 

 

recently been added or the door was kept

 

 

open for a long period of time, in both

 

 

cases, allow adequate time for the cabinet

 

 

to recover its normal operating temperature.

 

c.

Check door gasket for proper seal.

 

 

 

4. Food compartment is too cold.

a.

Adjust the thermostat to a warmer

 

 

setting.

 

 

 

5. Condensation on the exterior surface.

a.

Condensation on the exterior surface of the

 

 

unit is perfectly normal during periods of

 

 

high humidity.

 

b.

Check door alignment and gaskets for

 

 

proper seal.

 

 

 