X. TROUBLE SHOOTING GUIDE
FIND YOUR PROBLEM HERE |
| REMEDY |
|
|
|
1.Condensing unit fails to start. | a. | Check if line has been disconnected. |
| b. | Check |
| c. | Check switch behind louvers. |
|
|
|
2. Condensing unit operates for | a. | Shortage of refrigerant, locate and repair |
prolonged periods or continuously. |
| leak, evacuate and recharge per the |
|
| manufacturer’s requirements. |
| b. | Dirty condenser or filter. Clean properly. |
| c. | Are doors closing properly? |
| d. | Evaporator coil iced. Check defrost clock and |
|
| heating element. |
| e. | Check to see if there are any restrictions in |
|
| refrigeration system. |
|
|
|
3. Food compartment is too warm. | a. | Thermostat setting too high, readjust |
|
| thermostat. |
| b. | Perhaps a large quantity of food has |
|
| recently been added or the door was kept |
|
| open for a long period of time, in both |
|
| cases, allow adequate time for the cabinet |
|
| to recover its normal operating temperature. |
| c. | Check door gasket for proper seal. |
|
|
|
4. Food compartment is too cold. | a. | Adjust the thermostat to a warmer |
|
| setting. |
|
|
|
5. Condensation on the exterior surface. | a. | Condensation on the exterior surface of the |
|
| unit is perfectly normal during periods of |
|
| high humidity. |
| b. | Check door alignment and gaskets for |
|
| proper seal. |
|
|
|