TMB Programmable Multiband Amplifier

TMB 10A TMB 10B TMB 10S

GB

Programming the unit

A 4-digit display and a keypad are all you need to programme the unit. Follow the procedure below for configuring the various parameters.

CHAN LEVEL IN SAT

Digit 1

Digit 2

Digit 3

Digit 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

____ CARD AUTO ____

When the unit is powered on:

the programme mode is in standby:

by default, the system is configured as follows:

 

o

UHF1

Î

3 UHF filters

 

o

UHF2

Î

0 UHF filters

 

o

UHF3

Î

7 UHF filters

all the UHF filters are deactivated (display "- -"),

the attenuators are at zero.

Factory reset

If necessary, to revert to factory settings, follow the procedure below:

1.Disconnect the power cable

2.Press the esc button and hold it

3.Connect the power cable

The unit erases all the programming parameters, including the PIN code, and switches to standby mode.

You can release the esc button when the display shows “8888

Date of manufacture

If necessary, to consult the unit’s date of manufacture and version, press the button - & +. For 2 seconds, the unit displays the date of manufacture in the format; A-SSwith A being the last digit of the year of manufacture, SS the week of manufacture.