Tricity Bendix BIW 102 installation instructions Water drainage

Models: BIW 102

1 32
Download 32 pages 35.55 Kb
Page 28
Image 28
Water drainage

Water drainage

This appliance is designed to be permanently plumbed into your home's water supply and drainage system.

The appliance drain hose should hook (use the plastic “U-piece” supplied) into a standpipe with an internal diameter of approximately 38mm (see diagram) thus ensuring there is an air break between the drain hose and standpipe.

3 pin

 

 

90 cm.(35.4")

cm.

 

Max.

Min.60

(23.6")

P1039

 

 

When discharging into a standpipe ensure that the top of the curve in the hose end is no more than 90cm (35.4'') and no less than 60cm (23.6'') above floor level. The upright standpipe should have a minimum length of 30cm (12'') from the bottom of the elbow to the top of the pipe (see diagram).

Make sure that it is designed in such a way, that the end of the drain hose cannot be covered with water.

The drain hose may be extended to a maximum of 3 metres. An additional drain hose and joining piece is available from your local Service Force Centre.

The joining piece must have an internal diameter of 18mm.

Min. 30 cm.(12")

P1040

1

38 mm.(1/2") diameter

standpipe

If you intend the drain hose to empty into a sink, make sure that the sink is empty and the plug hose is not blocked. Use the plastic “U-piece” supplied.

P0022

28

Page 28
Image 28
Tricity Bendix BIW 102 installation instructions Water drainage