.The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 420 mm. If it is fitted below 420 mm a space of 55 mm must be allowed from the edges of the hob.

.The minimum distance combustible material can be fitted directly above the hob is 700 mm.

.If a cooker hood is installed above the hob, a clea- rance height of 650 mm must be allowed.

This appliance conforms to Type Y (IEC 335-2-6) with regard to fire protection. Only appliances of this type may be installed on one side of adjacent cabinets or walls.

Installation

.Cut the worktop according to the prescribed dimen- sions. See fig. 1. Saw exactly along the scribed line.

.Place according to figure 2.

Fastening according to fig. 3

.Tighten bracket against the underside of the work- top. Fix according to figur 3.

.Using a screwdriver, tighten the tension clamps evenly starting at the centre and moving diagonally until the built-in rim is tight on the worktop.

.Do not over tighten.

.Do not use an electric or pneumatic screwdriver without an adjustable safety clutch.

min. 650 mm

 

fig 1

 

radius

 

R5

 

width

490 + 1

560 + 1

depth

R5

radius

Points for fixing clamps

fig 2

560

490 +1

+1

fig 3

hobs frame

Ceramic glass plate

 

worktop

Einbaukasten

 

fixing clamp

 

Page 14
Image 14
Tricity Bendix TBC 650 BL manual 560 490 +1