The waste connection must be at a height of between 30 cm (minimum) and 100 cm (maximum) from the bottom of the dishwasher.

The drain hose can face either to the right or left of the dishwasher

Ensure the hose is not bent or squashed as this could prevent or slow down the discharge of water.

If you use a drain hose extension it must be no longer than 2 metres and its internal diameter must be no smaller than the diameter of the hose provided.

Likewise the internal diameter of the couplings used for connections to the waste outlet must be no smaller than the diameter of the hose provided.

The sink plug must not be in place when the machine is draining as this could cause the water to siphon back into the machine.

Electrical connection

This appliance must be earthed.

The manufacturer declines any responsibility should this safety measure not be observed.

If the plug that is fitted to your appliance is not suitable for the socket, it must be cut off and the appropriate plug fitted.

Important

The wires on the mains lead are coloured in accordance with the following code:

Green and Yellow

-Earth

Blue

-Neutral

Brown

-Live

If you fit your own plug, the colours of the wires in the mains lead of your appliance may not correspond with the markings identifying the terminals in your plug.

Proceed as follows:

1.Connect the Green and Yellow (earth) wire to the

terminal in the plug which is marked with the letter "E" or

the earth symbol

or coloured green and yellow.

2.Connect the Blue (neutral) wire to the terminal in the plug which is marked with the letter "N" or coloured black.

3.Connect the Brown (live) wire to the terminal in the plug which is marked with the letter "L" or coloured red.

The plug moulded onto the lead incorporates a 13amp BSI362 fuse. Only ASTA or BSI fuses should be used.

The plug must not be used if the fuse cover/carrier is lost. The cover/carrier is indicated by the coloured insert at the base of the product.

A replacement cover/carrier must be obtained from your local Service Force Centre.

This appliance complies with the following E.E.C. Directives:

-73/23 or 19.2.73 (Low Voltage Directive) and subsequent modifications;

-89/336 or 3.5.89 (Electromagnetic Compatibility Directive) and subsequent modifications.

Ø 18

Ø 21

 

 

 

 

cm

 

+ 2 m max

max 100

min 30 cm max 100 cm

 

 

CS10

 

 

 

CE03

11

Page 18
Image 18
Tricity Bendix TBDW 41 manual Electrical connection, Proceed as follows