Tricity Bendix TBF 610 Installation, Electrical Connection, Technical Data, Dimensions of recess

Models: TBF 610

1 20
Download 20 pages 24.52 Kb
Page 17
Image 17
Installation

Installation

The oven must be installed according to the instructions supplied.

This oven must be installed by qualified personnel to the relevant British Standards.

Technical Data

 

Heating elements rating

 

Dimensions of recess

 

Convection element

2,000 W

 

Grill

1,650 W

Height

580 mm

Oven Light

25 W

Width

560 mm

Depth

550 mm

Cooling Fan

25 W

 

 

Convection Fan

25 W

Dimensions of the oven cavity

 

Total Rating

2,075 W

Height

335 mm

Supply voltage (50 Hz)

230 V

Width

395 mm

 

 

Depth

400 mm

 

 

Oven capacity

53 litres

 

 

Electrical Connection

The oven is designed to be connected to 230 V (50 Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Data THIS OVEN MUST BE EARTHED

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

The yellow and green earth cable should be 2-3 cm. longer than the other cables.

Important

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For Uk use only

Connection

Min. size

Cable / flex

Fuse

via

Cable/flex

type

 

• 13 A socket

2.5 mm2

3 core

13 A

outlet

 

butyl

min.

• 13 A

 

insulated

 

spur box

 

 

 

 

 

 

 

• Cooker

2.5 mm2

PVC/PVC

15 A min.

Control

 

twin and

20 A max.

Circuit

 

earth

 

For Europe use only

Min. size Cable/flex

Cable / flex type

Fuse

 

 

 

1.5 mm2

H07 RN-F, H05 RN-F,

13 A

 

H05 RR-F, H05 VV-F,

 

 

H05 V2V2-F (T90),

 

 

H05 BB-F

 

 

 

 

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

Themanufacturerdisclaimsanyresponsibilityshould these safety measures not be carried out.

17

Page 17
Image 17
Tricity Bendix TBF 610 Installation, Electrical Connection, Technical Data, Heating elements rating, Dimensions of recess