4 Configuring the Receiver
34 AgGPS 252 Receiver User Guide
Note – The AgRemote utility, when connected to an AgGPS 252 receiver
receiver, automatically resets the receiver port communication settings to
8-O-1 TSIP 115 K. This enables optimal communication with an office
computer. If the receiver is to work with an Autopilot system, however, the
receiver port communication settings must be 8-N-1 TSIP 38.4 K. To work
with some other devices and software programs, the receiver port
communication settings must be 8-N-1 NMEA 4800. If AgRemote has
changed the settings, you will need to change them back manually.
When using a Trimble SiteNet 900 radio, make sure that the
communication settings are correct in the receiver.
The default settings to use with the SiteNet radio are:
Changing the input or output port settings
1. From the Port A Config screen, press 2 until the Port-A
Input/Output screen appears:
2. Press 3 to activate the cursor.
3. Press 1 or 2 to change the value.
4. Press 3.
5. Repeat Steps 3 and 4 until you have set all the required values.
6. Press 4 to save all the changes.
7. Press 2 to move to the next screen.
Setting Description
Baud rate 38,400
Data bits 8
Parity None
Stop bits 1
åæ I RTCM 96008N1 0 NMEA 4800
Ag252_100B_UserGuide_ENG.book Page 34 Thursday, July 28, 2005 4:06 PM