Trion 600M manual Description, New Unit Inspection, Position Air Cleaner Cabinet

Models: 600M

1 16
Download 16 pages 31.67 Kb
Page 2
Image 2

DESCRIPTION

The Trion MP 600M air cleaner is designed to capture machine tool fluids, metal dust and smoke for clean air filtration. It can be mounted to a wall, frame, platform, or directly on the machine tool. Mist, dust, and smoke are drawn from each machine through an external duct into the air cleaner. A self-draining Impinger removes the heavy mist and droplets (including water soluble fluids), and the remaining contaminates are captured by the pre- filter and the primary filter. Clean air is returned to the plant through the vertical discharge. The air cleaner operates at 95-99.97% efficiency at the rated 600 CFM airflow.

NEW UNIT INSPECTION

At the time the unit is received, all shipping containers and their contents should be examined for damage. Any damage occurring in shipment must be immediately reported to the carrier, an inspection report completed and a claim filed at the receiving point. The unit cabinet is shipped completely assembled

POSITION AIR CLEANER CABINET

To reduce weight for ease in handling, remove the pre- filters, main filters and place them safely aside. Position the cabinet in the designated location giving consideration to following points:

(a)Provide sufficient clearance in front of the access doors for mechanical filter replacement. A minimum of 26” is required (see figure 2).

(b)Level the cabinet to assure proper drainage from the drain pan.

(c)Unless specific design features have been prearranged, the direction of air flow through th e cabinet may be from any side or upward through the bottom. When the filters are reinstalled, the directional arrows on the filters must concur with airflow through the cabinet. If mist suppressors have been specified, they are to be installed on the air entering side of the unit.

After the cabinet has been properly located, it may be secured into place at the mounting pads either by bolting or welding.

2

Page 2
Image 2
Trion 600M manual Description, New Unit Inspection, Position Air Cleaner Cabinet