CAUTION:
When using flex duct connections with other than straight runs of duct, 45 degree elbows should be used to connect ducting to flanged collars to maximize air flow.
ENCLOSED MACHINING CENTER DIRECT MOUNT
1.When mounting directly to an enclosed machining center ensure there is 53” (135 cm) clearance above the enclosure and structure integrity is sufficient to support the MP 600M.
2.Open the filter access door and remove all the filtering elements. Set these components aside until the installation is complete.
3.Prepare an outlet opening on the top of he enclosed machining center (8” minimum to 20” maximum diameter opening).
4.Center the MP600M over opening and secure to the enclosure with
ARM ASSEMBLY (OPTIONAL) MOUNTING
Mount the arm assembly(s) to the arm connection collar on the inlet plenum in accordance with the mounting instructions provided in the arm assembly kit.
TRAPEZE MOUNT
1.Four (4) through holes are provided in the inlet plenum bottom flange to which two (2) mounting channels are affixed with 3/8” hardware (not provided).
2.The MP600M can be suspended from overhead with chains or 3/8” diameter (minimum) rods (not provided).
3.The inlet plenum is equipped with a ½” half coupler to connect drain piping. Plumbing should be routed to the collection point to facilitate drainage (P – trap not Required).
4.Affix duct(s) or elbow fitting(s) or flex hose(s) to the inlet plenum flange collar using hose clamps or other similar connection method (not provided).
1.Gauge may be mounted directly on MP600M unit or may be remotely mounted for improved visibility.
2.Gauge may be connected to measure entire system static pressure or only pressure drop across filter section.
3.All hardware, components and detailed installation instructions are included in gauge kit option.
Figure 3 - MP 600M Wall Mounted with 8” Arm Assembly and Drain Pipe