(1)First determine if the short is in the ionizing section or the collecting section by connecting each high voltage lead to its respective section, one at a time, and energizing the power pack. (The lead not con- nected must be supported away from any point of contact.) The short symptoms will still exist for the section in which the short is located. If the trouble causing the short is bridging both sections, then the short will be indicated in both sections when they are individually connected.

(2)When the short is isolated to a cell tier, remove all the cells within the tier and visually check the sec- tions indicated to contain the short.

(a). If the short is in the ionizer section look for a broken or defective insulator.

(b). If the short is in the collector section look for a large piece of foreign material bridging the collector plates or a defective insulator.

(c). If the short is indicated to be in both sections, it will probably be a foreign object bridging the air gap between the ionizer and the collector.

c.Open Circuits

Although open circuits can occur in the secondary they usually take place in the primary. If the unit contains only one power supply and the indicating light does not glow the outage is probably one of the following. (1) Supply line power to the control disconnected. Reconnect.

(2)Open access door interlock in control of electronic air cleaner. Be sure all access doors are properly closed and secured.

(3)Outage in the power supply. Look for charred or burned components or a loose wiring connection. Replace power supply or reconnect wiring.

(4)Defective indicating light. Replace light.

d. Malfunctions other than short or open circuits. Refer to trouble reference chart in this section.

8.Spare Parts

Recommended spare part quantities are usually based on the unit size and the amount of units per installation. For specific recommendations, consult the Trion factory or nearest Sales Office. Consideration, however, should be given to stocking the following components;

DESCRIPTION

QTY.

Complete Power Supply

1

Power Supply Indicating Light

1

Ionizing-Collect Cell Insulator

6

Trion Detergent

55 gal.

Part Numbers are not listed as they are subject to change. Always state Unit Model and Serial Numbers when ordering parts.

12

Page 14
Image 14
Trion Air Boss ATS, 147207-001 manual Spare Parts, Description QTY

147207-001, Air Boss ATS specifications

The Trion Air Boss ATS, model number 147207-001, represents a significant advancement in air quality management technology, designed to cater to both residential and commercial environments. This innovative air purification system combines state-of-the-art features with cutting-edge technologies to ensure optimal air quality.

At the heart of the Trion Air Boss ATS is its multi-stage filtration system. The system incorporates a pre-filter that captures larger particles such as dust and pet dander, ensuring that these allergens are eliminated before they can circulate through the air. Following this, a high-efficiency particulate air (HEPA) filter is employed, which is capable of capturing 99.97% of particles as small as 0.3 microns. This includes microscopic allergens, smoke, and even some bacteria and viruses. The result is clean, breathable air that helps reduce allergy symptoms and improve overall indoor air quality.

One of the standout features of the Trion Air Boss ATS is its advanced ionization technology. By introducing negatively charged ions into the air, it helps to further neutralize airborne contaminants. These ions attach to pollutants, causing them to clump together and fall out of the air, making it easier for the filters to capture them. This technology not only enhances air purity but also ensures that the space remains fresher and healthier.

The Trion Air Boss ATS is also designed with user convenience in mind. It features an intuitive control panel that allows users to easily monitor air quality levels and adjust settings as needed. Additionally, the system is equipped with smart sensor technology that automatically adjusts filtration speed based on the level of pollutants detected in the air, ensuring efficient operation without unnecessary energy consumption.

Energy efficiency is another hallmark of the Trion Air Boss ATS. The system is designed to minimize energy usage while maximizing air cleaning capabilities, making it an environmentally responsible choice. It is suitable for areas up to a specified square footage, making it versatile for various settings, from small offices to larger spaces.

In summary, the Trion Air Boss ATS, 147207-001, stands out for its effective multi-stage filtration, advanced ionization technology, user-friendly controls, and energy-efficient design. As air quality concerns continue to rise, this system offers a reliable solution for creating cleaner, healthier indoor environments.