Tripp Lite 700DV Plug the UPS into a wall outlet supplying either 120V or, nominal AC power

Models: 700DV

1 12
Download 12 pages 7.28 Kb
Page 3
Image 3
1Plug the UPS into a wall outlet supplying either 120V or 230V

200511135 93-2513 SMART700DV OM.qxd 1/12/2006 3:28 PM Page 3

Quick Installation

1Plug the UPS into a wall outlet supplying either 120V or 230V

(nominal) AC power.

Use the included detachable power cord. The IEC-320 end connects to the AC input receptacle on the rear of the UPS; the NEMA 5-15 end connects to the wall outlet.

To plug the UPS into a wall outlet that does not accept a NEMA 5-15 plug, simply replace the included power cord with a detachable cord from another piece of equipment, such as a computer. Then, use the includ- ed power cord to connect the equipment to the UPS.

NOTE! After you plug the UPS into a live AC outlet, the UPS (in “Standby” mode) will automatically charge its batteries,* but will not supply power to its outlets until it is turned ON (see Step 3 below).

* The BATTERY CHARGE LED will be the only LED illuminated.

1

2

2 Plug your equipment into the UPS.

 

NOTE! Your UPS is designed to support only elec-

 

tronic equipment. You will overload the UPS if the

 

total VA ratings for all the equipment you connect

 

exceeds the UPS's Output Capacity (700VA). To find

 

your equipment's VA ratings, look on their name-

 

plates. If the equipment is listed in amps, multiply

 

the number of amps by 120 to determine VA.

 

(Example: 1 amp × 120 = 120 VA). If you are unsure if you have overloaded

3

the UPS's outlets, see “OUTPUT LOAD LEVEL” LED description.

 

3Turn the UPS ON.

Press and hold the “ON/OFF/STANDBY” button for one second. The alarm will beep once briefly after one second has passed. Release the button.

3

Page 3
Image 3
Tripp Lite 700DV owner manual Plug the UPS into a wall outlet supplying either 120V or, nominal AC power, Turn the UPS ON