3
Feature Identification
Identifythepremiumfeaturesonyourspecificmodelandquicklylocate instructionsonhowtomaximizetheiruse.
Configuration DIP Switches: optimize Inverter/Charger
operation depending on your application. See Configuration
section for setting instructions.
Operating Mode Rocker Switch: controls Inverter/Charger
operation. The “AUTO/REMOTE” setting ensures your
equipment receives constant, uninterrupted AC power. It also
enables the Inverter/Charger to be remotely monitored and
controlled with an optional remote module (Tripp Lite model
APSRM4, sold separately). The “CHARGE ONLY”setting
allows your batteries to return to full charge faster by turning the
inverteroff,whichhaltsbatterydischarging.The"OFF"position
de-energizestheunit(includingitsACoutput).See Operation
section for setting instructions.
OperationIndicator Lights: intuitive “traffic light” signals
show whether the Inverter/Charger is operating from AC line
power or DC battery power. It also warns you if the connected
equipment load is too high. See Operation section for
instructions on reading indicator lights.
BatteryIndicatorLights: intuitive “traffic light” signals show
approximatechargelevelofyourbattery.SeeOperation section
for instructions on reading indicator lights.
DCPowerTerminals: connect to your battery terminals. See
BatteryConnection section for connection instructions.
HardwireACInput/OutputTerminalStrip(Access Panel):
securely connects the Inverter/Charger to facility electrical
system. See Input/Output Connection section for connection
instructions.
KnockoutsforACInput/OutputConduits
RemoteControlModuleConnector: allows remote monitoring
andcontrolwithanoptionalmodule(TrippLitemodelAPSRM4,
sold separately). See remote module owner’s
manual for connection instructions.
BatteryChargeConserver(LoadSense) Control: conserves
battery power by setting the low-load level at which the Inverter/
Charger’s inverter automatically shuts off. See Configuration
section for setting instructions.
MainGroundLug: properly grounds the Inverter/Charger to
earth ground. See BatteryConnection section for connection
instructions.
Thermostatically-Controlled Cooling Fans: quiet, efficient
fans regulate internal temperature and prolong equipment
servicelife.Fansrunatvariablespeed,dependingontemperature
and load.
Remote Generator Start Connector: automatically cycles
generator based on battery voltage. Use with user-supplied
cable. See Configuration section for more information.
RemoteBatteryTemperature SensingConnector: prolongs
batterylife byadjusting chargebasedon batterytemperature.
Contact Tripp Lite for optional temperature sensing cable
accessory. See Configuration section for more information.