Features

1Operating Mode Switch: controls Inverter/ Charger operation. When this switch is set to “AUTO”, connected equipment receives constant, uninterrupted utility AC power, with simultaneous charging of connected batteries. The “CHARGE ONLY” setting prevents unwanted battery rundown when there is no need for battery backup. Connected batteries are recharged. When the Operating Mode Switch is set to “DC OFF”, both the inverter and the battery charger are shut off. However, the unit will still pass utility AC power to connected equipment if it is plugged into an AC outlet.

2“OPERATION” Indicator Lights: These intuitive “traffic light” signals show whether the Inverter/Charger is operating from AC line power or from DC battery power. They also signal an alert if the connected equipment load is too high. See the Operation section for details.

3 “BATTERY” Indicator Lights: These “traffic light” signals show the approximate charge level of your battery. See the Operation section for details.

4AC Input: IEC 60320 C14 connects the Inverter/Charger to a source of utility- or generator-supplied AC power. See the AC Connection section for instructions.

5 AC Output: IEC 60320 C13 permits connection of equipment that would normally be plugged into a utility outlet. Note: The unit will always pass AC power to connected equipment if plugged into a live AC outlet, regardless of the position of the Operating Mode Switch.

6 Circuit Breaker: Protects the Inverter/ Charger against damage due to overload. See the Operation section for resetting instructions.

7Low Line Adjustment: Sets the AC input voltage at which the Inverter/Charger will switch from utility AC power to inverted battery power, allowing you to optimize operation in areas with frequent brownouts. If the dial is set fully counterclockwise, the unit will allow AC input to drop to approximately 160 V before switching to inverter mode. Note: The unit will continue to pass lower-voltage AC utility power to connected equipment until the unit switches to inverter mode.

8DC Connectors: Connect to your battery terminals with user-supplied cabling. See Battery Connection section for instructions.

9 Cooling Fan: Regulates internal temperature and prolongs equipment service life.

10 Main Ground Lug: Grounds the Inverter/ Charger to earth ground or vehicle grounding system. See Battery Connection section for instructions.