Features (Rear Panel) continued

Power Module Feature Description

1.Output Terminal Block (6kVA and 10kVA models only): Use these terminals to connect your power module to your equipment or to the transformer module. Unscrew and remove the cover over the block for access.

2.Input Terminal Block (6kVA and 10kVA models only): Use these terminals to connect your power module to utility power or to the transformer module. Unscrew and remove the cover over the block for access.

3.External Battery Connector: Use this to connect one or more Tripp Lite battery modules to the power module. Remove the cover for access. The power module will not start without a connection to a charged battery module. Refer to the battery module owner’s manual for connection instructions and safety warnings.

4.AC Input Breaker (6kVA and 10kVA models only): One double-pole circuit breaker controls input power to the power module.

5.AC Output Breaker (6kVA and 10kVA models only): One double-pole circuit breaker controls output power from the power module.

6.Exhaust Fan: This cools and ventilates the inside of the power module.

7.Accessory Slot: Remove the small cover panel to install optional accessories to remotely control and monitor your UPS system. Visit Tripp Lite on the Web (www.tripplite.com) to learn about available SNMP, network management and connectivity products that may be installed in this slot.

8.EPO (Emergency Power Off) Port: The power module features an EPO port that may be used to connect the power module to a contact closure switch to enable emergency power off. See “Optional Connection” section for details.

9.RS-232 Communication Port: This female DB9 serial port may be used to connect your UPS to a workstation or server. It uses RS-232 protocol to communicate with a connected computer. It is used with Tripp Lite software and the included serial cable to monitor and manage the UPS remotely over a network and to automatically save open files and shut down equipment during a blackout. See “Optional Connection” for details.

10.Dry Contact Interface Port: This female DB9 port sends contact-closure signals to indicate line-fail and low-battery status. See “Optional Connection” for details.

11.AC Output 1 Breaker (5kVA models only): One double-pole circuit breaker controls output power from the 5kVA power module's AC receptacles labelled "Output 1."

12.AC Output 1 Receptacles (5kVA models only): Accepts direct plug-in connection of NEMA L6-20P equipment plugs.

13.AC Output 2 Receptacles (5kVA models only): Accepts direct plug-in connection of NEMA L6-30P equipment plugs. Either receptacle also accepts direct plug-in connection of transformer connector cable (if used).

14.AC Input Cord (5kVA models only): Connects directly to wall receptacle providing 200/208/220/230 or 240V AC utility power.

Transformer Module Feature Description (Transformer Module not included with hardwire (HV) models.)

15.Utility Input Terminal Block (6kVA and 10kVA models only): Use these terminals to connect your transformer module to utility power. Unscrew and remove the cover over the block for access.

16.Equipment Output Terminal Block (6kVA and 10kVA models only): Use these terminals to connect your equipment to the trans- former module. Unscrew and remove the cover over the block for access.

17.Cable for Power Module Connection (6kVA models only): Connects the transformer module to the power module’s input/output after the power module’s terminal blocks have been removed. See “Connection” section for details.

18 Hardwire Terminal Block for Power Module Connection (10kVA models only): Use these terminals to connect the transformer mod- ule to the power module’s input and output terminal blocks. See “Connection” section for details.

19.Overtemperature Reset Breaker: This circuit breaker trips if the unit’s temperature climbs too high.

20.AC to UPS Breaker (6kVA and 10kVA models only): One double-pole circuit breaker controls the transformer module’s power output to the UPS.

21.Output Breaker (6kVA and 10kVA models only): One triple-pole circuit breaker controls the transformer module’s power output to connected equipment.

22.Manual Bypass Switch (6kVA and 10kVA models only): This red and yellow dial is used to circumvent the power module while still supporting connected equipment when performing power module maintenance. While this switch is on BYPASS, connected equipment will receive filtered AC mains power from the transformer module, but the equipment will not receive battery power in the event of a blackout. See “Manual Bypass Operation” section for complete bypass procedure.

WARNING! For qualified service personnel only. Failure to follow the bypass procedure completely will not

adequately power down the UPS power module, resulting in the continued risk of death or injury from potential

contact with high voltage.

9

Page 9
Image 9
Tripp Lite BP240V10RT-3U owner manual Features Rear Panel, Power Module Feature Description

BP240V10RT-3U specifications

The Tripp Lite BP240V10RT-3U is a robust battery pack designed to extend the runtime of compatible Tripp Lite UPS systems. With an impressive construction and advanced features, it caters to users requiring reliable backup power for critical applications.

One of the standout features of the BP240V10RT-3U is its scalability. It can be connected with other compatible battery packs to expand backup capacity, delivering users the flexibility to customize their power solutions based on specific requirements. This makes it an excellent choice for both small businesses and enterprise-level environments.

The BP240V10RT-3U is equipped with 10U of rack space, making it suitable for standard 19-inch racks. This design enhances easy integration within existing setups, allowing users to optimize their server or network rooms without sacrificing vital space. The compact design, combined with its lightweight construction, ensures that installation and transport do not become cumbersome tasks.

In terms of power, the BP240V10RT-3U features a high-capacity 240-volt output, which ensures that it can support multiple devices simultaneously, providing ample backup for various applications, from servers to network equipment. The UPS systems that are compatible with this battery pack are known for their efficiency and ability to deliver consistent power, making the BP240V10RT-3U an essential companion for those systems.

The battery pack also features hot-swappable batteries, allowing users to replace the batteries without shutting down connected devices. This feature is crucial in mission-critical environments where uptime is essential. Maintenance becomes convenient and non-disruptive, enabling organizations to stay operational while ensuring their power sources are always in optimal condition.

For monitoring and management, the BP240V10RT-3U can integrate seamlessly with Tripp Lite’s software solutions, providing users with visibility into battery status and power conditions. This connectivity ensures that potential issues are addressed promptly, enhancing overall reliability.

With a combination of scalability, power output, and easy maintenance, the Tripp Lite BP240V10RT-3U stands out as a leading choice for those seeking an efficient and reliable expandable battery pack. Its features make it particularly appealing for businesses looking to safeguard their operations against power interruptions while maintaining a streamlined and organized infrastructure.