Specifications
| Isobar | Isobar 4 | Isobar 6 | Isobar 8 RM |
AC Energy Absorption (Joules): | 600 | 2200 | 2350 | 2350 |
Amp Spike Protection (Amps): | 48,000 | 85,000 | 97,000 | 97,000 |
Dimensions (H x W x D): | 2½ x 5 x 3½" | 2½ x 6 x 3½" | 2½ x 7 x 3½" | 2½ x 9½ x 3½" |
| Isobar 4 Ultra | Isobar 6 Ultra | Isobar 8 Ultra | Isotel |
AC Energy Absorption (Joules): | 2200 | 2350 | 2350 | 2700 |
Amp Spike Protection (Amps): | 85,000 | 97,000 | 97,000 | 92,000 |
Dimensions (H x W x D): | 2½ x 6 x 3½" | 2½ x 7 x 3½" | 2½ x 9 x 3½" | 2½ x 6 x 3½" |
| Isotel 4 Ultra | Isotel 6 Ultra | Isotel 8 Ultra Multimedia |
AC Energy Absorption (Joules): | 2700 | 2850 | 2850 |
Amp Spike Protection (Amps): | 92,000 | 92,000 | 97,000 |
Dimensions (H x W x D): | 2½ x 6 x 3½" | 2½ x 7 x 3½" | 2½ x 9 x 3½" |
ALL MODELS:
•UL 1449 Listed (330V
•UL 1283 Listed (noise reduction)
Rated Input Voltage: | 105 to 135V AC; 60 Hz; (120V AC nominal) |
AC Outlets: | NEMA |
AC Line Cord: | 6', 14 gauge, |
| (12' on Isobar 8 Ultra, Isotel 8 Ultra Multimedia |
| and Isobar 8 RM models) |
Controls: | Illuminated RED "ON/OFF" switch |
| (Remote "ON/OFF" switch with 7' cord on Isobar 8 RM) |
High Frequency Noise Suppression: | > 20db @ 50Khz |
| > 40db @ 500Khz |
| > 75db @ 1Mhz |
| > 30db @ |
Transient Response Time: | Instantaneous* |
*Transient amplitude reduction occurs faster than the clamp response of the varistors because of the high rejection rate of the ISOBAR/ISOTEL filter networks.
TELEPHONE SURGE PROTECTION (ISOTEL AND ISOTEL ULTRA MODELS ONLY):
• UL 497A Listed (secondary communications protection)
Peak Transient Input Voltage: | 6Kv, 10 microseconds |
Energy Absorbtion: | 140 Joules |
Response Time: | Less than 5 nanoseconds |
Clamping Voltage: | 235 peak, ±10% |
EMI Noise Reduction: | Up to 27 db |
Input/Output Connector: | Female RJ11 jack; |
| (Isotel 6 Ultra features |
FCC PART 68 NOTICE (U.S. ONLY)
IfyourIsotelorIsotelUltracausesharmtothetelephonenetwork,thetelephonecompanymaytemporarilydiscontinueyourservice.Ifpossible, they will notify you in advance. If advance notice isn’t practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper operation of your equipment. If it does, you will be given advance notice to give you an opportunity to maintain uninterrupted service. If you experience trouble with this equipment, Isotel or Isotel Ultra, please contact the Manager of Technical Support; Tripp Lite; 1111 W. 35th Street, Chicago, Illinois 60609; Phone: (773)
3