6
Link Fault Pass-Through
(continued)
WARNING
The LFP (Link Fault Pass-Through) function works only when
two converters working as a pair have LFP capability.
Furthermore, both LFP converters should be supplied by the
same manufacturer/vendor.If you are using an odd number of
converters,or models that don’t support LFP, then the LFP
function will not work.
LED Description
LED Color Function
FX LNK/ACT Green Lit when FX port is linking
Blinks when FX port is transmitting data
FX FDX/COL Amber Lit when full-duplex mode is active
Off when half-duplex is active
Blinks when a collision occurs
TP LNK/ACT Green Lit when TPport is linking
Blinks when FX port is transmitting data
TP 100 Green Lit when TP port is transmitting data at 100 Mbps
Off when TP port is transmitting data at 10 Mbps
PWR Green Lit when +5V power is supplying
Cable Connection Parameter
TPCable Limitations: Cat. 5 and up to 100m
ConverterFiber Cable Limitations: Multi mode 2 km
Specifications
Standards: IEEE802.3u 10/100Base-TX, 100Base-FX
Flow Control:IEEE802.3x compliant for full-duplex back pressure flow control for
half-duplex
FiberCable: 50/125, 62.5/125 or 100/140 μm multi-mode
Wavelength:1310 nm
PowerRequirement: 1A@+5VDC from AC-DC Adapter, 0.5@+5VDC from USB port
Ambient Temperature:0° to 50°C
Humidity:5% to 90%
Dimensions:26.2 (H) x 70.3 (W) x 94 (D) mm
Complies with FCC Part 15 Class Aand CE Mark
200605219 93-2565 N784 SMC OM.qxd 6/7/2006 3:54 PM Page 6