Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the installation, operation, and storage of this product. Failure to heed these instructions and warnings will void the product warranty.

The PDU provides convenient multiple outlets, but it DOES NOT provide surge or line noise protection for connected equipment.

The PDU is designed for indoor use only in a controlled environment away from excess moisture, temperature extremes, conductive contaminants, dust or direct sunlight.

Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that eliminate the connection to ground.

The power requirement for each piece of equipment connected to the PDU must not exceed the individual outlet’s load rating.

The total power requirement for equipment connected to the PDU must not exceed the maximum load rating for the PDU.

Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable parts inside.

Do not attempt to modify the PDU, including the input plugs and power cables.

Do not attempt to use the PDU if any part of it becomes damaged.

Do not attempt to mount the PDU to an insecure or unstable surface.

Never attempt to install electrical equipment during a thunderstorm.

Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.

Installation

Mounting the PDU

The PDU supports five primary mounting configurations: 1U Rack, 0U Rack (Vertical), Wall, Under- Counter and Reduced-Depth.

Note: Regardless of configuration, the user must determine the fitness of hardware and procedures before mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may not be appropriate for all applications. Exact mounting configurations may vary. Screws for attaching the mounting brackets and cord retention shelf to the PDU are included. Use only the screws supplied by the manufacturer, or their exact equivalent (#6-32, ¼" flat head).

1-11U Rack Mounting: Use 4 screws A to attach each of the 2 longer mounting brackets B to the PDU as shown. You can mount the PDU in a recessed position by attaching the mounting brackets so they extend beyond the front panel of the PDU. (If you plan to use the cord retention shelf, attach the mounting brackets in a recessed position.) Mount the PDU in the rack by inserting 4 user-supplied screws C through the mounting brackets D and into the mounting holes of the rack rails.

A

A

B

D

C

1-1

2

Page 2
Image 2
Tripp Lite PDUMH20HVNET owner manual Important Safety Instructions, Mounting the PDU

PDUMH20HVNET specifications

The Tripp Lite PDUMH20HVNET is a robust power distribution unit (PDU) designed to enhance the efficiency and reliability of data centers and IT environments. This PDU is particularly valuable for those needing remote management capabilities, as it combines advanced features with a versatile design to meet various power distribution needs.

One of the primary characteristics of the PDUMH20HVNET is its ability to support high voltage applications. With an input voltage range of 200-240V, it is compatible with various high-performance equipment. The unit provides a total of 20 amps of power, making it suitable for powering multiple devices while ensuring efficient load balancing across the outlets.

The PDUMH20HVNET features 20 NEMA 5-15R output receptacles, allowing for the connection of multiple devices without sacrificing performance. This distribution unit offers both horizontal and vertical mounting options, granting flexibility for any rack-mounted equipment. Its compact design enables it to fit easily into standard 19-inch racks, saving valuable space in crowded server rooms.

Another notable feature of the PDUMH20HVNET is its built-in network management capabilities. It comes equipped with an Ethernet port that allows for remote monitoring and management via a web interface. Users can track real-time data regarding current loads, voltage, and environmental conditions, enabling proactive management of power resources. This feature is essential for maintaining optimal performance and preventing overload situations.

The unit also includes advanced features like automatic alerts for power fluctuations, allowing for quick responses to any issues that may arise. Additionally, it supports SNMP for seamless integration with existing network management systems, simplifying the overall monitoring process.

Durability and safety are other key aspects of the PDUMH20HVNET. It is constructed with high-quality materials to withstand the rigors of daily use in demanding environments. The built-in surge protection safeguards connected devices from spikes and surges, ensuring the longevity of critical equipment.

In summary, the Tripp Lite PDUMH20HVNET is a feature-rich power distribution unit that delivers reliable performance and remote management capabilities. Its high voltage support, flexible mounting options, and advanced monitoring features make it an essential component for modern data centers and IT operations, contributing to efficient and safe power management.