Tripp Lite RS-0615-R, IBAR 12 Specifications, UL 1283 All IBAR models, for line-noise filtering

Models: RS-1215 RS-1215-RA IBAR 12 ULTRA DRS-1215 RS-0615-R RS0615F IBAR 12 RS-1215-HG

1 16
Download 16 pages 51.85 Kb
Page 3
Image 3
Specifications

200112060 Isobar RM Metal Owner’s Manual 93-2028.qxd 1/3/02 2:48 PM Page 3

Specifications

 

IBAR12

IBAR12ULTRA

IBAR12/20ULTRA

AC Energy Absorption (joules):

750

1200

1200

Surge Suppression (amp spikes)*:

60,000

96,000

96,000

UL 1449 Let-Through Rating:

400V

330V

330V

HF Noise Suppression (@ 1 MHz)

 

 

 

Filter Bank #1:

40 dB

40 dB

80 dB

Filter Bank #2:

80 dB

80 dB

AC Receptacles:

2 NEMA 5-15R (front)

2 NEMA 5-15R (front)

2 NEMA 5-15R (front)

 

10 NEMA 5-15R (back)

10 NEMA 5-15R (back)

10 NEMA 5-15/20R (back)

AC Line Cord:

15', w/NEMA 5-15P plug

15', w/NEMA 5-15P plug

15', w/NEMA 5-20P plug

Circuit Breaker (Resettable):

15 amp

15 amp

20 amp

Dimensions (HxWxD, inches):

1¾ × 17½ × 4

1¾ × 17½ × 4

1¾ × 17½ × 4

Weight (lbs.):

5

5

5.4

 

IBAR12-20T

RS-1215

RS-1215-20

AC Energy Absorption (joules):

1200

NONE

NONE

Surge Suppression (amp spikes):

96,000

NONE

NONE

UL 1449 Let-Through Rating:

330V

HF Noise Suppression (@ 1 MHz)

 

 

 

 

 

Filter Bank #1:

80 dB

NONE

NONE

Filter Bank #2:

NONE

NONE

AC Receptacles:

2 NEMA 5-15R (front)

6

NEMA 5-15R (front)

6

NEMA 5-20R (front)

 

10 NEMA 5-15/20R (back)

6

NEMA 5-15R (back)

6

NEMA 5-20R (back)

AC Line Cord:

15', w/L5-20P plug

15', w/NEMA 5-15P plug

15', w/NEMA 5-20P plug

Circuit Breaker (Resettable):

20 amp

15 amp

20 amp

Dimensions (HxWxD, inches):

1¾ × 17½ × 4

1¾ × 17½ × 4

1¾ × 17½ × 4

Weight (lbs.):

5.4

5

 

5

 

 

RS-1215-RA

RS-1215-HG

DRS-1215

AC Energy Absorption (joules):

NONE

NONE

450

Surge Suppression (amp spikes):

NONE

NONE

36,000

UL 1449 Let-Through Rating:

330V

HF Noise Suppression (@ 1 MHz)

 

 

 

 

Filter Bank #1:

NONE

NONE

NONE

Filter Bank #2:

NONE

NONE

NONE

AC Receptacles:

6 NEMA 5-15R (front)

6

15A hospital grade (front)

6 NEMA 5-15R (front)

 

6 NEMA 5-15R (back)

6

15A hospital grade (back)

6 NEMA 5-15R (back)

AC Line Cord:

15', w/NEMA 5-15P plug

15', w/15A hospital grade plug 15', w/NEMA 5-15P plug

Circuit Breaker (Resettable):

15 amp

15 amp

15 amp

Dimensions (HxWxD, inches):

1¾ x 17½ x 4

1¾ x 17½ x 4

1¾ x 17½ x 4

Weight (lbs.):

5

5

 

5

 

RS-0615-R

RS-0615-F

AC Energy Absorption (joules):

NONE

NONE

Surge Suppression (amp spikes):

NONE

NONE

UL 1449 Let-Through Rating:

HF Noise Suppression (@ 1 MHz)

 

 

Filter Bank #1:

NONE

NONE

Filter Bank #2:

NONE

NONE

AC Receptacles:

6 NEMA 5-15R (back)

6 NEMA 5-15R (front)

AC Line Cord:

15', w/NEMA 5-15P plug

15', w/NEMA 5-15P plug

Circuit Breaker (Resettable):

15 amp

15 amp

Dimensions (HxWxD, inches):

1¾ x 17½ x 4

1¾ x 17½ x 4

Weight (lbs.):

5

5

* Spike protection is provided in all three modes: hot to neutral, hot to ground and neutral to ground.

All Models: Nominal Input Voltage: 120VAC; Input Frequency: 50/60 Hz

All IBAR Models: Transient Response Time: Instantaneous (0 ns). Transient amplitude reduction occurs faster than the clamp response of the varistors because of the high rejection rate of the ISOBAR filter networks.

UL 1449 (1999 rev.): IBAR12ULTRA, IBAR12/20ULTRA, IBAR12-20T and DRS-1215:

330V let-through (UL’s best rating for surge suppression); IBAR12: 400V let-through

UL 1283: All IBAR models, for line-noise filtering

CUL: meets Canadian National Standards as certified by UL

3

Page 3
Image 3
Tripp Lite RS-0615-R, RS-1215-HG, IBAR 12 Specifications, All Models Nominal Input Voltage 120VAC Input Frequency 50/60 Hz