Cooling method | Fan |
|
|
Battery Access | Battery access panel allows hot swap replacement without powering connected equipment off. |
|
|
ENVIRONMENTAL |
|
Relative Humidity | 0 to 95%, |
|
|
Storage Temperature | +5 to +122 degrees Fahrenheit / |
|
|
Operating | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Temperature |
|
|
|
Line mode BTU/hr. | 168.2 BTU/hr. (worst case) |
(Max.) |
|
|
|
Battery mode | 604.4 BTU/hr. (worst case) |
BTU/hr. (Max.) |
|
|
|
COMMUNICATIONS |
|
Network monitoring | |
port |
|
|
|
Software and cabling | Includes PowerAlert UPS monitoring software for all common network and standalone operating systems. Ships with 2 |
included | cables, |
|
|
SNMP compatibility | |
|
|
WatchDog | Yes, compatible with Tripp Lite's WatchDog system service software to restore operation to locked equipment through |
compatibility | soft reboot of application / OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk |
| applications |
|
|
LINE / BATTERY TRANSFER
Transfer time from line power to battery mode
Low voltage transfer | Switches to battery power if line voltage decreases to 83 (120V), 87 (110V), or 83 (100V) volts or less. Resets back to |
to battery power | line power as line voltage increases to 87 (120V), 92 (110V), or 87 (100V) volts or higher. |
|
|
High voltage transfer | Switches to battery power as line voltage increases to 145 (120V), 133 (110V), or 121 (100V) volts or higher. Resets |
to battery power | back to line power when line voltage decreases to 141 (120V), 129 (110V), or 118 (100V) volts or less. |
|
|
SPECIAL FEATURES |
|
EPO port | Includes RJ11 EPO (emergency power off) port and interconnection cable |
|
|
TVSS grounding | Includes back panel grounding point with thumbscrew for data line surge suppressors and other network accessories |
| requiring a safe grounding point |
|
|
Cold Start
Yes, inverter can be "cold started" to enable temporary AC output during a power failure
Appearance
Attractive
BATTERY PACK ACCESSORY (optional)
Battery Pack | BP48V242U (limit 1) and BP48V60RT3U |
Accessory (optional) |
|
|
|
CERTIFICATIONS |
|
Certifications | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), RoHS compliant, Class A (Emissions), NOM (Mexico) |
|
|
WARRANTY |
|
Product Warranty | 2 year product warranty |
Period |
|
|
|
Connected | $250,000 connected equipment insurance (USA / Canada only) |
Equipment Coverage |
|
|
|
Optional Coverage
3 year, 5 year, next day and
Related Items
Audio Cables
CT120 | |
|
|
Qty: [optional]