Tripp Lite SMARTINT3000VS, SMARTINT2200VS owner manual Storage & Service, Specifications

Models: SMARTINT2200VS SMARTINT3000VS

1 11
Download 11 pages 56.75 Kb
Page 10
Image 10
Storage

Storage & Service

Storage

Before storing your UPS, turn it completely OFF: with the UPS ON and receiving utility power, press and hold the ON/OFF/STANDBY button for one second (an alarm will beep once briefly after the interval has passed); then, unplug the UPS from the wall outlet. If you store your UPS for an extended period of time, recharge the UPS batteries once every three months: plug the UPS into a wall outlet; allow it to charge for up to 4 hours; and then unplug it and place it back in storage. Note: after you plug the UPS in, it will automatically begin charging its batteries; however, it will not supply power to its outlets (see Quick Installation section). If you leave your UPS batteries discharged for an extended period of time, they will suffer a permanent loss of capacity.

Service

Before returning your UPS for service, follow these steps:

1.Review the installation and operation instructions in this manual to ensure that the service problem does not originate from a misreading of the instructions. Also, check that the UPS System's circuit breaker(s) are not tripped. This is the most common cause of service inquiries which can be easily remedied by following the resetting instructions in this manual.

2.If the problem continues, do not contact or return the UPS to the dealer. Instead, call Tripp Lite at (773) 869-1233. A service technician will ask for the UPS's model number, serial number and purchase date and will attempt to correct the problem over the phone.

3.If the problem requires service, the technician will issue you a Returned Material Authorization (RMA) number, which is required for service. If you require packaging, the technician can arrange to send you proper packaging. Securely pack the UPS to avoid damage during shipping. Do not use Styrofoam beads for packaging. Any damages (direct, indirect, special, incidental or consequential) to the UPS incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty. UPS Systems shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid. Mark the RMA number on the outside of the package. If the UPS System is within the 2-year warranty period, enclose a copy of your sales receipt. Return the UPS for service using an insured carrier to the address given to you by the Tripp Lite service technician.

Specifications

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Model:

SMARTINT2200VS

SMARTINT3000VS

Series #:

AGSM4839

AGSM4840

Input

 

 

Nominal Voltage/Frequency:

230VAC 50/60 Hz

230VAC 50/60 Hz

Output

 

 

Capacity (VA/Watts):

2200/1600

3000/2250

On Line Nominal Voltage/Waveform:

230VAC/sine wave

230VAC/sine wave

On Battery Nominal Voltage/Waveform:

230VAC/PWM sine wave

230VAC/PWM sine wave

Battery Runtime (Half Load/Full Load) Minutes:

19/7

14/4+

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

Approvals:

CE, GOST, SASO, IRAM

CE, GOST, SASO, IRAM

ALL UNITS: Voltage-Regulated Output Voltage Range: -18% / +8%. On-Battery Output Voltage Range: ± 5 %. AC Surge Suppression (exceeds IEEE 587 Cat. A & B stan- dards); AC Noise Attenuation (>40 dB at 1MHz); AC Protection Modes (H to N, H to G, N to G).

“+” Battery runtime can be extended with addition of optional Tripp Lite External Battery Pack (sold separately). SMARTINT3000VS uses BP48V18 battery pack. External battery will increase both the battery runtime and the battery recharge time.

Note on Labeling

Two symbols are used on the label.

V~ : AC Voltage

VService : DC Voltage