Tripp Lite instruction manual Highlights, Description, Features, Model # SU10KRT3UHV

Models: SU10KRT3UHV

1 5
Download 5 pages 16.8 Kb
Page 1
Image 1
Model #: SU10KRT3UHV

Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com

Model #: SU10KRT3UHV

SmartOnline Expandable Rack / Tower UPS System - On-line, double-conversion protection for mission critical applications

Highlights

Highlights 10,000VA (10kVA) / 8,000W on-line 6U rack / tower UPS (3U Power Module + 3U Battery Pack)

Description Enhanced serial communications ports, SNMP/Web card slot and EPO jack

Features Maintains 200, 208, 220, 230 or 240V output +/-2% during brownouts to 156 and overvoltages to 276V

Manual background Internal fault tolerant auto bypass mode and detachable hardwired PDU with manual bypass switch enables hot-swap UPS replacement without powering off connected loads

Manual background Expandable runtime with optional battery packs

Manual background $250,000 Ultimate Lifetime Insurance (USA, Puerto Rico & Canada only)

Description

Tripp Lite 10,000VA (10kVA) SmartOnline Rack/Tower UPS. The SmartOnline SU10KRT3UHV on-line, double conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage fluctuations and surges in a compact tower/rackmount housing. In rack configuration, power module and battery pack occupy only 3 rack spaces each (6U total). Upright tower placement of entire system supported with included tower stands. Large capacity 10,000VA/8000W power module converts raw input AC to DC, then back to perfect sine wave AC output within 2% of user-selectable 200/208/220/230/240V AC output voltages. Frequency regulation locks output power to 50/60Hz (+/-0.2 Hz), removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Perfectly regulated, continuous sine wave output with zero transfer time offers guaranteed compatibility with all equipment types. Hardwire input and output connections support a variety of permanent or PDU style power connections. Detachable hardwired PDU with manual bypass switch enables hot-swap UPS replacement without powering off connected loads. Battery support can be extended through the addition of optional external battery packs, sold separately. Includes slot for internal SNMP/Web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data.

Applications

Manual background Ideal for protection of critical 200/208/220/230/240V equipment in server rooms, internetworking closets and telecommunications systems in rackmount or tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems.

Package Includes

Manual background SU10KRT3UHV Rack-Tower UPS System with hardwire distribution module and 1 battery pack

Manual background PowerAlert Software and cabling

Manual background Mounting hardware for 4 post rack enclosures/tower stands

Manual background Instruction manual with warranty information

Features

Manual background True on-line, double conversion UPS provides pure, sine wave AC output at all times Manual background World-wide compatibility with Euro 50Hz and High Voltage North American 60Hz power