Tripp Lite user manual Highlights, Description, Features, Model # SU8000RT3U

Models: SU8000RT3U

1 7
Download 7 pages 11.04 Kb
Page 1
Image 1
Model #: SU8000RT3U

Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com

Model #: SU8000RT3U

SmartOnline 8kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V NEMA outlets

Highlights

Highlights 8kVA / 8000VA / 7200W on-line double-conversion UPS; 0.9 power factor

Description 200/208/220/230/240V 50/60Hz output; Economy mode option

Features 6U Rack/Tower compatible; Hot-swap power and battery modules

Manual background USB, RS232 & EPO ports; SNMP/WEB and contact-closure card options

Manual background Front panel LEDs with detailed LCD monitoring and control screen

Manual background Expandable runtime with optional external battery packs

Manual background Hardwire input (3 wire); L6-30R & L6-20R outlets

Description

Tripp Lite SU8000RT3U 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete power protection for critical network

applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications.

Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with

manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced

availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers,

computer rooms, network closets and rugged industrial locations.

Package Includes

Manual background SU8000RT3UPM 3U UPS power module

Manual background BP240V10RT3U external battery pack

Manual background SUPDMB710 Detachable PDU with manual bypass switch

Manual background Four post compatible rack rail kit (2 sets)

Manual background Tower stands for upright tower configuration

Manual background PowerAlert software, complete data cabling and user manual

Features

Manual background Tripp Lite SU8000RT3U 8kVA / 8000VA / 7200 watt on-line, double-conversion UPS system in 6U total rack/tower configuration (3U UPS power module and 3U external battery pack)

Manual background Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to connected networking equipment

Manual background Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Manual background Hardwire input; 2 L6-30R and 4 L6-20R outlets

Manual background Maximum installed rack depth of only 32.5 in. / 82.6cm inches

Manual background Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise

Manual background Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types

Page 1
Image 1
Tripp Lite user manual Highlights, Description, Features, Model # SU8000RT3U