Tripp Lite warranty Highlights, Description, Model # SU8000RT3UHW

Models: SU8000RT3UHW

1 5
Download 5 pages 13.92 Kb
Page 1
Image 1
Model #: SU8000RT3UHW

Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com

Model #: SU8000RT3UHW

SmartOnline Expandable Rack/Tower UPS System - Online, double conversion protection for mission-critical applications

Highlights

Highlights 8000VA (8kVA) on-line 6U rack/tower UPS with expandable runtime (3U power module + 3U battery pack)

Description Zero transfer time, on-line, double-conversion and economy-mode operation supported

Manual background Detachable hardwired PDU with manual bypass switch enables hot-swap UPS replacement without powering off connected loads

Manual background 200/208/230/240V selectable input/output voltage

Manual background 2% output voltage regulation over an input voltage range of 156V to 276V

Manual background Enhanced serial communication ports, SNMP/Web Card Slot and EPO interface

Manual background $250,000 Ultimate Lifetime Insurance (USA & Canada only)

Description

8000VA (8kVA) on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Installs in only 6 rack spaces (3U power module and 3U battery pack). Maximum installed rack depth of 32.5 in. Expandable battery runtime with optional external battery packs. Full-time sine wave 200, 208, 220, 230, or 240V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 156V and overvoltages to

276V. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Standard 3-wire 208V hardwire input and output connections. Detachable hardwire input-output PDU module with manual bypass switch enables hot-swap UPS replacement without disrupting power to connected equipment. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support communications via RS-232, contact-closure port and optional SNMPWEBCARD slot. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs offer at-a-glance confirmation of line power status, battery power status, AC-to-DC conversion, DC-to-AC conversion, bypass mode and output power status. LCD panel with scroll buttons offers detailed diagnostic test information at startup and during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage and battery charge level. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories and 2-9USTAND tower kit included; 2POSTRMKITWM 2-post rackmount hardware accessories available.

Field replaceable, hot-swappable power module and external battery packs. Attractive all-black color scheme. 2-year warranty and $250,000connected e connected equipment insurance;extended warranty and service contracts available.

Applications

Manual background Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection. Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems

Package Includes

Manual background 3U power module with detachable hot-swap PDU input/output panel and bypass switch

Manual background 3U external battery pack

Manual background Two sets of 4 post rackmount rails (one for each of the 3U components)