VOLTAGE REGULATION

Expandable battery runtime

Connects to UPS via

DC system voltage

Typical battery lifespan

Battery recharge rate

Runtime is expandable with optional external battery packs

Included 3-wire DC cable

240VDC

4-6 years

Less than 8 hours to 90% (included battery set only)

VOLTAGE REGULATION

Voltage regulation description

Overvoltage correction

Brownout correction

On-line, double-conversion process give this UPS the ability to maintain output voltage within +/-2% of selected nominal voltage at all times

Maintains continuous operation without using battery power during overvoltages to 276V AC, regulating output within 2% of selected nominal

Maintains continuous operation without using battery power during brownout / undervoltage conditions to 156V AC, regulating output within 2% of selected nominal

LEDS ALARMS & SWITCHES

Front panel LEDs

Alarms

Switches

6 LED DISPLAY: line power, bypass, inverter, charger, output AC and battery operation. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations

Multi-function audible alarm offers notification of UPS start, backup operation, low battery, overload, UPS fault, inverter fault, DC bus fault, overtemperature, remote shutdown, shutdown imminent and shutdown complete

Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions

SURGE / NOISE SUPPRESSION

AC suppression

Instantaneous

response time

 

 

 

EMI / RFI AC noise

Yes

suppression

 

 

 

PHYSICAL

 

Shipping weight (lbs)

331

 

 

Shipping weight (kg)

150.3

 

 

Shipping

39.75 x 31.5 x 23

Dimensions (HWD/in)

 

 

 

Shipping

101 x 80 x 58.4

Dimensions

 

(HWD/cm)

 

 

 

Unit weight (lbs)

Power Module 55 lbs., Battery Pack: 136.5 lbs.

 

 

Unit weight (kg)

Power Module 25 kg., Battery Pack: 62 kg

 

 

Unit Dimensions

Power Module 5.14 x 17.5 x 25, Battery Pack 5.16 x 17.5 x 25 (Installed depth of power module extends to 32.5 inches

(HWD/in)

once detachable PDU backplate is installed)

 

 

Unit Dimensions

Power Module 13.3 x 44.4 x 63.5, Battery Pack 13.4 x 40.6 x 63.5 (Installed depth of power module extends to 82.6 cm

(HWD/cm)

once detachable PDU backplate is installed)

 

 

Material of

Steel

construction

 

 

 

Form factors

Rack (6U)

supported

 

 

 

Cooling method

Fan

 

 

Battery Access

User replaceable, hot swappable external battery pack

 

 

ENVIRONMENTAL

 

Relative Humidity

0 to 95%, non-condensing

 

 

Storage Temperature

+5 to +122 degrees Fahrenheit

 

 

Operating

+32 to +104 degrees Fahrenheit

Temperature

 

 

 