SPECIFICATIONS

 

 

No. of

AC Line Cord*

Surge Energy

Surge

 

Transient

 

 

 

AC Receptacles

Length

Absorption

Current

EMI/RFI

Response

Dimensions

Model

(NEMA 5-15R)

(ft.)

(joules)

(amps)

Noise Filtering

Time (NM)

(H x W x D, in.)

 

 

 

 

 

 

 

 

 

SUPERSURGEALERT

6

6

1500

78,500

>80 dB

0 ns.

1½ x 3½ x 9½

SUPERSURGEALERTPLUSTEL

6

6

2100

85,00

>80 dB

0 ns.

1½ x 3½ x 9½

 

 

 

 

 

 

 

 

 

SUPER8

8

8

1200

54,500

>60 dB

<1 ns.

1½ x 2½ x 13

SUPER8PLUSTEL

7

8

1500

78,500

>60 dB

<1 ns.

1½ x 2½ x 13

 

 

 

 

 

 

 

 

 

SUPER7

7

7

1050

42,500

>40 dB

<1 ns.

1½ x 2¾ x 11¼

SUPER7PLUSTEL

6

7

1200

54,500

>40 dB

<1 ns.

1½ x 2¾ x 11¼

SUPER7PLUSCOAX

6

7

1200

54,500

>40 dB

<1 ns.

1½ x 2¾ x 11¼

SUPER 7 PLUS TEL/15

6

15

1200

54,500

>40 dB

<1 ns.

1½ x 2¾ x 11¼

 

 

 

 

 

 

 

 

 

SUPER6

6

3.5

450

36,000

>20 dB

<1 ns.

1¼ x 3¼ x 8¼

SUPER6PLUSTEL

6

3.5

450

36,000

>20 dB

<1 ns.

1¼ x 3¼ x 8¼

SUPER6DELUXE

6

6

1050

42,500

>20 dB

<1 ns.

1¼ x 3¼ x 8¼

SPIKE STIK

6

6

360

27,000

>20 dB

<1 ns.

1½ x 2½ x 10

4

ALLMODELS

Rated Input Voltage: 120V AC, 50 or 60 Hz

Rated Current and Load Handling: 15 amps maximum (1800) watts, 15 amps maximum per receptacle

Circuit Breaker: 15 amp resettable Exceeds IEEE category A & B specifications.

* All line cords are 14-gauge, 3-conductor grounded

TELEPHONELINESPECIFICATIONS(PLUSTELandDELUXEMODELS) Clamping Voltage: 260V peak (200V for SUPER 6 PLUS TEL) +/- 10% Response Time: <1 picosecond (<5 nanoseconds for SUPER 6 PLUS TEL) Peak Transient Input Voltage: 6 Kv, 10 microseconds

Input/Output Connectors: two female “RJ” style modular jacks (phone cable included); 2 wire, single line protection

COAXIALLINESPECIFICATIONS(PLUSCOAXMODELS)

 

Peak Pulse Power Dissipation: 12,000 amps

 

 

AC Energy Absorption: 120 joules

 

Insertion Loss: <1 dB

 

Input/Output Connectors: two female “F” connectors

Certified by UL

 

 

to Canadian National

 

 

Standards

UL 1449 330V let-through (UL’s best rating for surge suppression) UL 1363 for temporary power tap

UL 1283 for line-noise filtering

UL 497A for modem/fax protection (PLUS TEL & DELUXE models only) CUL: meets Canadian National Standards as certified by UL