Troubleshooting | 8 |
| |
|
|
Problem |
| Cause |
| Remedy |
|
|
|
|
|
|
|
|
|
|
Engine fails to start | 1. | Choke control not in ON position. | 1. | Move choke control to ON position. |
| 2. | Spark plug wire disconnected. | 2. | Connect wire to spark plug. |
| 3. | Fuel tank empty or stale fuel. | 3. | Fill tank with clean, fresh gasoline. |
| 4. | Engine not primed. | 4. | Prime engine as instructed in the Operation |
|
|
|
| section. |
| 5. | Faulty spark plug. | 5. | Clean, adjust gap, or replace spark plug. |
| 6. | Safety key not inserted . | 6. | Insert key fully into the switch. |
|
|
|
|
|
Engine runs erratic | 1. | Engine running on CHOKE. | 1. | Move choke lever to OFF position. |
| 2. | Blocked fuel line or stale fuel. | 2. | Fill tank with clean, fresh gasoline. |
| 3. | Water or dirt in fuel system. | 3. | Drain fuel tank. Refill with fresh fuel. |
| 4. | Carburetor out of adjustment. | 4. | Contact a Briggs & Stratton Service Center. |
|
|
|
|
|
Engine overheats | 1. | Carburetor not adjusted properly. | 1. | Contact a Briggs & Stratton Service Center. |
|
|
|
|
|
Excessive vibration | 1. | Loose parts or damaged auger. | 1. | Stop engine immediately and disconnect |
|
|
|
| spark plug wire. Tighten all bolts and nuts. If |
|
|
|
| vibration continues, have unit serviced by an |
|
|
|
| authorized Service Center. |
|
|
|
|
|
Loss of power | 1. | Spark plug wire loose. | 1. | Connect spark plug wire. |
| 2. | Gas cap vent hole plugged. | 2. | Remove ice and snow from gas cap. Be |
|
|
|
| certain vent hole is clear. |
|
|
|
|
|
Unit fails to propel itself | 1. | Drive control cable in need of adjustment. | 1. | Adjust drive control cable. Refer to |
|
|
|
| Maintenance and Adjustments section. |
| 2. | Drive belt loose or damaged. | 2. | Replace drive belt. Refer to Service section |
| 3. | Friction wheel worn. | 3. | Replace friction wheel. Refer to Service |
|
|
|
| section. |
|
|
|
|
|
Unit fails to discharge snow | 1. | Chute assembly clogged. | 1. | Stop engine immediately and disconnect |
|
|
|
| spark plug wire. Clean chute assembly and |
|
|
|
| inside of auger housing with |
|
|
|
| or a stick. |
| 2. | Foreign object lodged in auger. | 2. | Stop engine immediately and disconnect |
|
|
|
| spark plug wire. Remove object from auger |
|
|
|
| with |
| 3. | Auger control cable in need of adjustment. | 3. | Adjust auger control cable. Refer to Assembly |
|
|
|
| & |
| 4. | Auger belt loose or damaged. | 4. | Replace auger belt refer to Service section. |
| 5. | Shear pin(s) sheared. | 5. | Replace shear pin(s). |
|
|
|
|
|
23