Channel 1 signal can be heard in Channel 2 output - and vice versa.

Channel 2 seems to have no output when used with Channel 1 as a stereo pair

Check status of M-Sselector. It should be “out”for individual channel mode and “in”for Mid-Side mode.

Check status of M-Sselector. It should be “out”for individual channel mode and “in”for Mid-Side mode.

Make sure the φ selectors for both Channels 1 and 2 are “out”.

In M-S mode the stereo channels are reversed (Channel 1 is Right and Channel 2 is Left)

In M-S mode the stereo channel phasing is incorrect

Electric instrument connected to a Direct Input does not produce a signal or signal is distorted.

Make sure the front of the bi-directional “Side” mic is aimed 90 degrees to the right of the axis of the “Mid”mic.

Make sure the φ selectors for both Channels 1 and 2 are in the same position.

Check continuity of electric instrument cables. Check the batteries or AC power source of any “foot pedal”effects processors connected

to the Direct Input.

Make sure that the instrument cables have standard tip-sleeve 1/4” phone plugs. - DO NOT use TRS plugs.

Radio Frequency Interference can be heard in the audio program (swishing sound or audio from a radio transmitter).

Make sure that mic cables are of good quality and that the shield is properly connected. Avoid excessive length.

Make sure that earth ground connection is maintained via the AC power cord - DO NOT use an isolator.

Make sure the unit is located away from known sources of radio frequency energy.

.

REGISTRATION and WARRANTY

Don’t forget to register your PRECISION 8i by filling out the enclosed Registration Card and returning it to us. This allows TRUE Systems to contact you regarding any updates, upgrades or applications information that may become available.

SUNRISE ENGINEERING and DESIGN INC. (“SUNRISE”) warrants the TRUE systems PRECISION 8i to be free from defects in material and manufacture, when properly installed and used according to instructions in the Operation Manual, for a period of one year from the date of sale to the original purchaser. Units returned for warranty repair to SUNRISE or an authorized TRUE Systems repair facility will be