True Food Service Equipment, Inc.
MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be followed, including the following:
REQUIRED TOOLS:
•Phillips Screwdriver
•Stiff Bristle Brush
•Adjustable Wrench
• Air Tank or CO2 Tank • Vacuum Cleaner
Step 1
Disconnect power to unit.
Step 2
SLIDE DOOR MODELS: (See Image 1)
Take off lower grill assembly by removing two (2) screws in lower corners. (older models may have snap lock tabs instead of screws).
Loosen screws holding the top pivot pins. Swing grill up and remove frame hooks from pivot pins at top of louver.
SWING DOOR MODELS: (See Image 2)
Take off lower grill assembly by opening the door and removing screws from the top of the louver grill. Some models have a door light switch. Please use caution when removing the grill on these models. Do not pinch wires. For reinstall, reattach the grill to the magnets on front of the cabinet and reinstall the screws on top of the grill.
Step 3
Remove bolts anchoring compressor assembly to frame rails and carefully slide out. (tube connections are flexible)
Step 4
Clean off accumulated dirt from the condenser coil and the fan with a stiff bristle brush.
Step 5
Lift cardboard cover above fan at plastic plugs and carefully clean condenser coil and fan blades.
Step 6
INDOOR LOCATION:
After brushing condenser coil vacuum dirt from coil, and interior floor.
OUTDOOR LOCATION:
Step 7
Replace cardboard cover. Carefully slide compressor assembly back into position and replace bolts.
Step 8
Reinstall louver assembly onto unit with appropriate fastener and clips. Tighten all screws.
Step 9
Connect unit to power and check to see if compressor is running.
1
Slide Door Models
2
Swing Door Models
Image 3.
5 - 1227
Image 4.
15 | www.truemfg.com | 15 |