LOCATING

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

LOCATING

A.Remove louver from the front of cabinet (see page 17 for louver grill removal / reinstallation) and backguard (if applicable) from rear of cabinet.

B.Skid bolts are located in each of 4 corners inside cabinet bottom. (See photo A).

C.Remove skid bolts. (See photo B).

D.Cut straps if applicable. (See photo C).

E.Carefully lift cabinet off of skid.

LEVELING

A

Removing skid from bottom of cabinet.

B

C

A. Set unit in its final location. Be sure there is adequate

WARNING

 

ventilation in your room. Under extreme heat

Cabinet warranties are void if OEM power cord is tampered

 

conditions, (100°F+, 38°C+), you may want to install

with. TRUE will not warranty any units that are connected to

 

an exhaust fan.

an extension cord.

WARNING

 

Warranty is void if ventilation is insufficient.

 

B.

Proper leveling of your TRUE cooler is critical to

 

 

operating success (for non-mobile models). Effective

 

 

condensate removal and door operation will be

 

 

effected by leveling.

 

C.

The cooler should be leveled front to back and side

 

 

to side with a level.

 

D.

Ensure that the drain hose or hoses are positioned in

 

 

the pan.

 

E.

Free plug and cord from inside the lower rear of the

 

 

cooler (do not plug in).

 

F.

The unit should be placed close enough to the

 

 

electrical supply so that extension cords are never

 

 

used.

 

REMOTE UNITS (This section applies to remotes only!)

 

• Remote cabinets must be ordered as remote.

• Contact TRUE Technical Service for BTU

 

We do not recommend converting from a

requirements.

 

standard self contained to remote system.

• No wiring necessary between cabinet and

• All remote cabinets must be hard wired.

condensing unit.

No castors available.

• All remote condensing units purchased from

• All remote cabinets come standard using 404A

TRUE are 208/230 volts single phase.

 

refrigerant.

If you have any questions regarding this section, please

• All remote units come standard with expansion

call TRUE at 1-(800)-325-6152.

 

valve, liquid line solenoid, heated condensate

 

 

pan, and defrost timer when applicable.

 

5

............ www.truemfg.com

5

Page 7
Image 7