True Manufacturing Company TCGR-50 Temperature Control Adjustment For High Altitude Only, Terms

Models: TCGR-50 TCGR-50-CD

1 22
Download 22 pages 7.62 Kb
Page 17
Image 17

True Food Service Equipment, Inc.

MAINTENANCE, CARE & CLEANING

TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE ONLY!

TERMS:

NOTE

Cut-out - Temperature sensed by the controller

Mechanical temperature controllers are affected

 

that shuts the compressor off.

when functioning at high altitude. The Cut-in and

Cut-in - Temperature sensed by the controller

cut-out temperatures will be colder than when the

controller functions closer to sea level.

 

that turns the compressor on.

 

 

TOOLS REQUIRED:

D. For high elevation installations, it may be

necessary to "warm-up" the set points. To

Phillips head screwdriver

make the adjustment, insert the appropriate

5/64" or 2 mm Allen wrench

tool in each adjustment screw and turn 1/4

T-7 Torx wrench

of a revolution clockwise (to the right). This

 

 

A. Unplug or disconnect power to the cabinet.

procedure will adjust both the cut-in and cut-

out about 2°F warmer.

B. Remove the screws that secure the

E. Make sure to reconnect the wire to proper

 

temperature control to the inset box, lower

spade terminal when reinstalling.

 

 

right, rear of cabinet.

C.Pull out gently from cabinet.

DANFOSS TEMPERATURE CONTROL

Compressor

Connection

4

3

Cut-out Adjustment Screw Allen (5/64" or 2 mm) (clockwise for warmer)

Cut-in Adjustment Screw Torx (T-7)

(clockwise for warmer)

Compressor Connection (double terminal)

15

www.truemfg.com

15

Page 17
Image 17
True Manufacturing Company TCGR-50 Temperature Control Adjustment For High Altitude Only, Terms, Tools Required