True Manufacturing Company TDC-47 Cleaning The Condenser Coil, Covered By The Warranty, Step

Models: THDC-6 TDC-47

1 18
Download 18 pages 60.14 Kb
Page 14
Image 14
True Food Service Equipment, Inc.

True Food Service Equipment, Inc.

MAINTENANCE, CARE & CLEANING

CLEANING THE CONDENSER COIL

When using electrical appliances, basic safety precautions should be followed, including the following

True Dipping Cabinets are equipped with reversing fan motors keeping the condenser coil cleaner than the conventional fan motors.

TOOLS REQUIRED:

Phillips screwdriver

Stiff bristle brush

Adjustable Spanner or Mole Grips

Vacuum Cleaner

Step 1

Disconnect power to unit.

Step 2

Removing the four 1/4" hex head screws to allow removal of the rear grill. (See image 1).

Step 3

Remove bolts anchoring compressor assembly to frame rails and carefully slide out. (tube connections are flexible)

Step 4

Clean off accumulated dirt from the condenser coil and the fan with a stiff bristle brush. (See image 2).

Step 5

Lift cardboard cover above fan at plastic plugs and carefully clean condenser coil and fan blades.

Step 6

After brushing condenser coil vacuum dirt from coil, and interior floor. (See image 3).

Step 7

Replace cardboard cover. Carefully slide compressor assembly back into position and replace bolts.

Step 8

Reinstall rear grill assembly onto unit. Tighten all screws.

Step 9

Connect unit to power and check to see if compressor is running.

Image 2

Image 3

Image 1

THE CLEANING OF THE CONDENSER IS NOT

COVERED BY THE WARRANTY!

Condensers accumulate dirt and require cleaning every 30 days.

Dirty condensers result in compressor failure, product loss, and

lost sales... which are not covered by warranty.

If you keep the Condenser clean you will minimize your service expense and lower your electrical costs. The Condenser requires scheduled cleaning every thirty days or as needed.

Air is pulled through the Condenser continuously, along with dust, lint, grease, etc.

A dirty Condenser can result in NON-WARRANTEED part & Compressor Failures, Product Loss, and Lost Sales.

Proper cleaning involves removing dust from the Condenser. By using a soft brush, or vacuuming the Condenser with a shop vac, or using CO2, nitrogen, or pressurized air.

If you cannot remove the dirt adequately, please call your refrig- eration service company.

If you have any questions, please call True Manufacturing at 636- 240-2400 or 800-325-6152 and ask for the Service Department. Service Department Availability Monday-Friday 7:30 a.m. to 5:30 p.m. and Saturday 7:45 a.m. to 11:45 a.m. CST.