True Manufacturing Company TGU-2, TGU-3F Cleaning The Condenser Coil, Covered By The Warranty

Models: TGU-2 TGU-3F

1 12
Download 12 pages 11.05 Kb
Page 11
Image 11
True Food Service Equipment, Inc.

True Food Service Equipment, Inc.

MAINTENANCE, CARE & CLEANING

CLEANING THE CONDENSER COIL

When using electrical appliances, basic safety precautions should be followed, including the following

TOOLS REQUIRED:

• Phillips screwdriver

• Stiff bristle brush

• Adjustable Spanner or Mole Grips

• Vacuum Cleaner

Step 1

Image 1

Disconnect power to unit.

Image 2

Step 2

Removing the four Phillips screws to allow removal of the front grill.

Step 3

Remove bolts anchoring compressor assembly to frame rails and carefully slide out. (tube connections are flexible)

Step 4

 

Clean off accumulated dirt from the condenser

Image 3

coil and the fan with a stiff bristle brush.

 

(See image 1).

 

Step 5

Lift cardboard cover above fan at plastic plugs and carefully clean condenser coil and fan blades.

Step 6

After brushing condenser coil vacuum dirt from coil, and interior floor. (See image 2).

Step 7

Replace cardboard cover. Carefully slide compressor assembly back into position and replace bolts.

THE CLEANING OF THE CONDENSER IS NOT

COVERED BY THE WARRANTY!

Condensers accumulate dirt and require cleaning every 30 days. Dirty condensers result in compressor failure, product loss, and lost sales... which are not covered by warranty.

If you keep the Condenser clean you will minimize your service expense and lower your electrical costs. The Condenser requires scheduled cleaning every thirty days or as needed.

Air is pulled through the Condenser continuously, along with dust, lint, grease, etc.

Step 8

Reinstall rear grill assembly onto unit. Tighten all screws.

Step 9

Connect unit to power and check to see if

compressor is running.

A dirty Condenser can result in NON-WARRANTEED part & Compressor Failures, Product Loss, and Lost Sales.

Proper cleaning involves removing dust from the Condenser. By using a soft brush, or vacuuming the Condenser with a shop vac, or using CO2, nitrogen, or pressurized air.

If you cannot remove the dirt adequately, please call your refrig- eration service company.

If you have any questions, please call True Manufacturing at 636- 240-2400 or 800-325-6152 and ask for the Service Department. Service Department Availability Monday-Friday 7:30 a.m. to 5:30 p.m. and Saturday 7:45 a.m. to 11:45 a.m. CST.

9

www.truemfg.com

9

Page 11
Image 11
True Manufacturing Company TGU-2, TGU-3F installation manual Cleaning The Condenser Coil, Covered By The Warranty