True Manufacturing Company TMC-34-S Locating, Leveling, Compressor warranties are void if the

Models: TMC-49-S TMC-34-S TMC-58-S

1 16
Download 16 pages 29.96 Kb
Page 7
Image 7
LOCATING
Loosen castor bolts with an adjustable wrench enough to slide shims between the castor mount- ing plate and cabinet bottom.
If the cabinet is not level prop up one end of the cabinet between castors with a 6” block.
(See image 4)
Note:
Do not push block more than 5”
Four sets of shims have been provided in warranty packet for leveling castored units positioned on uneven floors. Shims must be positioned between cabinet and castor mounting plate. (See image 3)

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

LOCATING

Step 2

A. Remove skid by using a phillips head screwdriv- er and an adjustable wrench.

B.For easy removal from the skid, unscrew and remove grill from the back of the cooler.

C.Remove the four brackets from the base of the

cooler.

D.Carefully move the cooler off the back of the

skid. Tilt the cooler backwards just enough to remove the skid from under the cooler.

E. Free plug and cord from inside the lower rear of the cooler (do not plug in).

F. Place grill back onto rear of the cooler.

G. The merchandiser should be placed close enough to the electrical supply so that exten- sion cords are never used.

Image 1

WARNING:

Compressor warranties are void if the

unit is more than 9ft. (2.7 m) from

plug-in connection.

35° F°

LEVELING

Important Safeguard for installation of leg/castor (Images 1-5 demonstrate procedure)

Step 3LEVELING CASTORS A. Set unit in its final location. Be sure there is

adequate ventilation in your room. Under extreme heat conditions, (100 F+, 38 C+), you may want to install and exhaust fan.

WARNING:

Warranty is void if ventilation is insufficient.

B. Proper leveling of your True cooler is critical to operating success. Effective condensate removal and door operation will be effected by leveling. (See image 2)

C.

under cabinet.

When the cooler is in its final position adjust

the castors as needed to level the unit. The unit should be leveled front to back and side to side with a level. To insure proper ventilation for the compressor, keep the cabinet 1” (2.54 cm) from rear wall. 1” (2.54 cm) rubber bumpers are attached to the back of some cabinets.

5

www.truemfg.com

5

Page 7
Image 7
True Manufacturing Company TMC-34-S Locating, Leveling, Compressor warranties are void if the, under cabinet, Step