M1205 HDD Start-Mode  & ID Selection Switch
SW1 & SW2 HDD Start-Mode  Selection Switch
Case | SW1  | SW2  | Motor Spin Func- | 
  | (DLYD_START) | (RMT_START) | tion | 
  | 
  | 
  | 
  | 
1  | OFF  | OFF  | Motor spins up at  | 
  | 
  | 
  | D.C. power on.  | 
  | 
  | 
  | 
  | 
2*  | ON  | OFF  | Motor spins up at  | 
  | 
  | 
  | D.C. power on after  | 
  | 
  | 
  | a delay in seconds  | 
  | 
  | 
  | 12 times** the value  | 
  | 
  | 
  | of the numeric  | 
  | 
  | 
  | SEL_ID for the SCSI  | 
  | 
  | 
  | device.  | 
  | 
  | 
  | 
  | 
3  | OFF  | ON  | Motor spins up only  | 
  | 
  | 
  | when START UNIT  | 
  | 
  | 
  | command is  | 
  | 
  | 
  | received.  | 
  | 
  | 
  | 
  | 
4  | ON  | ON  | Reserved. SCSI  | 
  | 
  | 
  | devices not imple-  | 
  | 
  | 
  | menting this option  | 
  | 
  | 
  | shall execute power  | 
  | 
  | 
  | control according to  | 
  | 
  | 
  | the rules of case 3.  | 
  | 
  | 
  | 
  | 
Note:
*Case 2 is the default setting.
**This value may be reduced by SCSI device supplies to reflect the 
64  | Chapter 3: Replacing  |