PC1150 Keypad
The Zone Lights will come ON when the system is disarmed |
|
|
|
|
|
| |||||||
to indicate that there is activity in a zone. Refer to the System |
|
|
|
|
|
| |||||||
Information page at the front of this manual for zone information. | The “Ready” light will come ON to indicate | ||||||||||||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| that the system is ready to be armed. | |||||
|
|
|
|
|
|
|
| When the “Ready” light is OFF, there is an | |||||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| open zone on the system. All zones must | |||||
|
|
|
|
|
|
|
| be either secure or bypassed before the | |||||
|
|
| Zone 1 |
| Ready |
|
| ||||||
|
|
|
|
|
| system may be armed. |
|
|
| ||||
|
|
| Zone 2 |
| Armed |
|
|
|
|
| |||
|
|
| Zone 3 |
| System |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Zone 4 |
|
|
|
| The “Armed” light will come ON to | |||||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| indicate that the system is armed. To | |||||
|
|
| 1 | 2 | 3 |
|
| arm the system, first ensure that the | |||||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| “Ready” light is ON, then enter an | |||||
|
|
| 4 | 5 | 6 |
|
| ||||||
|
|
|
|
|
|
|
| Access Code. |
|
|
|
| |
|
|
| 7 | 8 | 9 |
|
| The “System” light is used to indicate a | |||||
|
|
|
|
|
|
|
| ||||||
|
|
|
| 0 | # ACCESS |
|
| number of conditions on the system that | |||||
|
|
|
|
|
|
|
| may require attention before the system is | |||||
|
|
|
|
|
|
|
| ||||||
|
| PC115O |
|
|
|
| armed. When the “System” light is ON, | ||||||
| DOC LN/MDC IC 2 |
|
|
|
|
| check the following: |
|
|
|
| ||
|
|
|
|
|
|
|
| • press [∗ ][1][9] | to | view | Bypassed | ||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| Zones | [∗ ][2] |
|
|
|
|
|
| Keypad Zones: |
|
|
|
| • press | to | view | Trouble | |||
|
|
|
|
|
| Conditions |
|
|
|
| |||
| Press [1]+[3] for 2 seconds to activate a Pulsed alarm |
|
| • press [∗ | ][3] to view the Alarm Memory | ||||||||
| Press [4]+[6] for 2 seconds to activate an Auxiliary alarm |
|
| Display |
|
|
|
|
| ||||
| Press [∗ ]+[#] for 2 seconds to activate a Panic alarm |
|
| Refer to this instruction manual for | |||||||||
| The Keypad Zones will not function unless they are enabled |
|
| complete instructions on using these | |||||||||
|
| by your Installer. |
|
|
|
| features. |
|
|
|
|
| |
|
|
|
|
|
|
|
| Press [#]... |
|
|
|
|
|
|
|
|
|
|
|
|
| • when an error is made in entering | |||||
|
|
|
|
|
|
|
| code, then enter code again. | |||||
| Trouble Conditions: The “System” light will come ON when there is a fault on |
| |||||||||||
|
|
|
|
|
|
|
| • to return to ready state after using | |||||
| the system. Press any key to silence the keypad sounder. Press [∗ ] then [2] |
| |||||||||||
|
|
|
|
|
|
|
| [∗ ] commands. |
|
|
|
| |
| to display the trouble condition. Call for service if you are unable to correct a |
| |||||||||||
| trouble condition. |
|
|
|
|
|
|
|
|
|
|
| |
|
| Light | Trouble Type |
| What to do |
|
|
|
|
| |||
|
| Zone 1 | Low battery |
| Call for service |
|
|
|
|
| |||
|
| Zone 2 | AC failure (keypad | Check fusebox for |
|
|
|
| |||||
|
|
| buzzer will not sound) | open fuses; call for service |
|
|
| ||||||
|
| Zone 3 | System Fuse open | Call for service |
|
|
|
|
| ||||
|
| Zone 4 | Fail to communicate | Call for service |
|
|
|
|
| ||||
|
| “Ready” | Not used to indicate troubles |
|
|
|
|
|
| ||||
|
| “Bypass” | Clock needs resetting | Reset the system time |
|
|
|
|
7