99 Adjust Door

Checking Door Alignment

The unit’s door is aligned at the factory before shipment. However, its alignment could have been disturbed during shipment.

IMPORTANT

Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps).

1.Carefully examine the door’s gasket to assure that it is firmly in contact with the cabinet.

2.When inspecting door alignment, make sure the door gasket is not pinched on the hinge side of the door.

Adjusting Door Alignment

BI-2115

1.Remove top hinge screw pin Remove door by tilting forward and lifting off bottom hinge pin.

2.With door upside-down, loosen but do not remove the two screws on the door’s bottom hinge plate.

10 Power Supply

Electrical Specifications

WARNING

SHOCK HAZARD — Electrical Grounding Required.

Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.

Never use an extension cord to connect power to the unit.

IMPORTANT

Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to

3. If the top far edge of the door

needs to move UP, move the

consult your local codes.

hinge plate toward the outside

of the door and retighten

screws. If the top far edge of

the door needs to move

DOWN, move the hinge plate

toward the inside of the door

and retighten screws.

Slotted

 

Mounting

Notch

Holes

(must face toward

 

center of door)

Raise

Lower

Outside

Outside

Door Edge

Door Edge

ADA15IM

23-1/8"

7"

SP18

26-5/16" Minimum

7"

4.Mount the door to recheck alignment and repeat Steps 2

and 3 if further adjustment is necessary.

5.

When top edge of door is

Door

 

parallel to top edge of cabinet,

Inserts

 

 

Closer

 

remove the door and ensure

 

 

the two screws are secure.

 

6.

Remove the door closers

Boss

 

from the bottom hinge, clean

 

thoroughly and lubricate the mating surfaces with petroleum jelly.

7.Reinstall the closers, lining up the bosses with holes in hinge and hinge plate.

8.Mount the door, install top hinge pivot pin

All Other Models

1-1/2"

BI95,WH95TP,BI95BTP & BCM95

18-1/2"

Minimum

7"

1-1/2"

BI98

1-1/2"

SS-1095(NF)(FC)(FD)

 

Preferred

 

Location

Acceptable

for Receptacle

Location

 

7"

1-1/2"

BI2115

1.Loosen (do not remove) top and bottom hinge screws.

2.Align door squarely with cabinet. Make sure gasket is firmly in contact with cabinet all the way around the door (no gaps).

3.Tighten bottom hinge screws.

4.Tighten top hinge screws.

24"